NAME
Access
(R/W)
Possible value on
the serial port of
the unit
Comments
Moodule
CONF.VSWR.MAX
R/W
XX.X X=[0..9]
Set the VSWR alarm threshold. Use a 3 digit
value. "020" => VSWR = 2. You cannot sent "2"
or "1.4".
DRVn |
PAn
CONF.VSWR_TRIG
R/W
"WARNING" or
"FAULT/WARN" or
"FAULT"
Working mode in case of VSWR overshoot.
WARNING = triggers a simple Warning.
WARN/FAULT = triggers a fault but does not
trigger the reflected protection. FAULT =
triggers a fault and the reflected protection
triggers a VSWR fault. Default value: FAULT
ECU |
DRVn
7.2.5.
Alarm commands
NAME
Access
(R/W)
Possible value on the
serial port of the unit
Comments
Module
ALARM.10MSWITCH
R
"ON" or "OFF"
Indicates there was a 10 MHz switch
ECU |
DRVn
ALARM.1DB
R
"ON" or "OFF"
ON =>1 dB Alarm, OFF => => No alarm
DRVn |
PAn
ALARM.24V
R
"ON" or "OFF"
ON =>24 V Alarm, OFF => => No alarm
ECU
ALARM.3DB
R
"ON" or "OFF"
ON =>3 dB Alarm, OFF => => No alarm
DRVn |
PAn
ALARM.AMB
R
"ON" or "OFF"
ON => ambient alarm, OFF => No alarm.
ECU |
DRVn |
PAn |
PSUn
ALARM.AUDIO.LOSS
R
"ON" or "OFF"
ON =>Audio loss Alarm, OFF => => No alarm. The alarm
is triggered when there is audio loss on all the inputs
as set with the commands
CONF.AUDIO.LOSS.SELECT.
xxx
ECU |
DRVn
ALARM.BATLOW
R
"ON" or "OFF"
Indicates if the NVRAM battery’s level is OK
ECU |
DRVn
ALARM.COMM
R
"ON" or "OFF"
Indicates if there is a communication fault with one of
the units of the system
ECU |
PSUn
ALARM.CUR1
R
"ON" or "OFF"
Indicates the PSU 1 current is over the max threshold.
DRVn |
PAn |
PSUn
ALARM.CUR2
R
"ON" or "OFF"
Indicates the PSU 2 current is over the max threshold.
PAn |
PSUn
ALARM.EEPROM
R
"ON" or "OFF"
Indicates an issue with calibration retrieval, it is either
false or unusable
PAn
ALARM.EXC_TEMP
R
"ON" or "OFF"
ON => indicates the temperature of the exciter is
higher than the max threshold
DRVn
ALARM.FAN1
R
"ON" or "OFF"
Fan 1 alarm; speed is too slow
ECU |
DRVn |
PSUn
ALARM.FAN2
R
"ON" or "OFF"
Fan 2 alarm; speed is too slow
ECU |
PSUn
ALARM.FAN3
R
"ON" or "OFF"
Fan 3 alarm; speed is too slow
ECU
ALARM.FAN4
R
"ON" or "OFF"
Fan 4 alarm; speed is too slow
ECU
ALARM.FAULT
R
"ON" or "OFF"
ON => critical alarm OFF => => No alarm (3 dB, VSWR)
ECU |
DRVn |
PAn |
PSUn
ALARM.HEAT1
R
"ON" or "OFF"
ON =>
heatsink
temp alarm, OFF => No alarm.
DRVn |
PAn |
PSUn
ALARM.HEAT2
R
"ON" or "OFF"
ON =>
heatsink
temp alarm, OFF => No alarm. (1500
& 2000 W modules only)
PAn |
PSUn