TROUBLESHOOTING
Symptom
Possible causes
Solution
Machine turns on but
it does not draw any
water or there is not
sufficient pressure.
Power nozzle is too high from the
water source surface.
Lower the machine below 5ft/1.5m.
The users garden hose is not well
connected to the machine.
Check and reattach the garden hose tightly. (See Fig. H2)
The pump filter screen is blocked.
(See Fig. X1, X2)
Clean the filter screen regularly.
Pump, hose, or other parts are frozen
due to outside temperatures.
Wait for the pump, hose or other parts to thaw.
Hose kinks.
Straighten out the hose.
Additional air could be sucked into
the machine.
If air builds up within the hose or pump, the water
pressure will drop. First, restart the machine, then
air will be released through the multi-spray nozzle
along with water.
Multi-spray nozzle
leaks.
The nozzle pattern does not spray
correctly.
Make sure the nozzle pattern symbol aligns with the
indicator mark on tool.
Fixing nail of the multi-spray nozzle
loosens.
Tighten it with a hex key.
Air built up within the hose or pump.
Continue to operate the machine for a few moments
until leakage stops.
Outlet pressure
increases suddenly.
Multi-spray nozzle is blocked.
Replace with a new multi-spray nozzle.
Machine drains out water
after stopping.
There is water remaining in the lance
and pump after stopping.
Drain all the water completely before storage.
Soap accessory
cannot spray out any
detergent.
Blockage in the soap bottle.
Clean it with fresh water.
The machine is not connected to
the water source.
Connect to the water source before turning on the
machine.
Machine does not start.
The battery pack is not attached well.
Reinstall the battery pack.
Battery pack is empty.
Replace with a new battery pack or recharge the battery
pack.
Defective battery.
Replace with a new battery pack.
Machine pressure is not
consistent.
Additional air could be sucked
into the machine.
Check connection between the hose adapter and
the draw hose.
It is at low pressure setting.
No action need.
Machine stops
automatically.
Battery pack is empty.
Replace with a new battery pack or recharge the
battery pack.
The multi-spray nozzle is blocked.
The current protection is activated.
Remove the multi-spray nozzle and turn on the
machine. If the machine works normally, replace with a
new multi-spray nozzle.
Machine does not draw
any water after long
time storage.
Additional air could be sucked into
the machine.
Connect the machine to the water source and then turns
it on.