10
RePLACe THe BRUsHes (see Fig. G1,G2,G3)
When the resin insulating tip(g)inside the carbon brush(h)is exposed
to contact the commutator(f), it will automatically shut off the motor.
When this occurs, both carbon brushes should be replaced as
following steps :
1) disconnect the plug from the power supply.
2) Unscrew the carbon brush cap (e) with screwdriver.
3) When brushes need replacement always renew both brushes.
4) Completely screw down the carbon brush cap. Check that the tool
is working. Before use, allow it run for a few minutes to enable the
brushes to settle.
CONsTANT eLeCTRONIC CONTROL
Constant electronic control holds the speed constant at no-load and
under load, and ensures uniform working performance.
OVeRLOAD PROTeCTION
If the tool insert becomes caught or jammed, the drive to the drill
spindle is interrupted. Because of the forces that occur, always hold
the power tool firmly with both hands and provide for a secure stance.
Working hints for your tool
Reduce the pressure on the drill bit when it is about to break through.
This will prevent the drill from jamming.
When drilling a large hole, first drill a pilot hole using a smaller drill bit.
Always apply pressure to your drill bit in a straight line, and if possible
at right angles to the workpiece.
Never change the operating mode whilst the drill is running.
do not apply excessive pressure to the tool when chiseling.
Expressive force does not speed up the work.
Maintenance
Remove the plug from the socket before carrying out any
adjustment, servicing or maintenance.
There are no user serviceable parts in your power tool. Never use
water or chemical cleaners to clean your power tool. Wipe clean with
a dry cloth. Always store your power tool in a dry place. Keep the
motor ventilation slots clean. Keep all working controls free of dust.
Occasionally you may see sparks through the ventilation slots. This is
normal and will not damage your power tool.
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified persons in order
to avoid a hazard.
Troubleshooting
The following table gives checks and actions that you can perform if your
machine does not operate correctly.
If these do not identify/solve the problem, contact WORX Customer
Service.
I would add a comment here to again recommend that you apply grease
to the shank of every drill bit used.
10
11
12
1
2
3
4
5