MRTALP8-DC3: #35059
Rev 8.0/1-20
34
Rated Load Test
1
The following steps must be performed or supervised by a qualified person:
2
1) Use a test load that weighs 125% (± 5%) of the Maximum Load Capacity and has the
appropriate “L
2) Attach the vacuum pads to the load as previously directed.
3) Position the load to produce the greatest stress on the lifter consistent with “INTENDED
4)
Take precautions in case
load should fall during test.
Raise the load a minimal distance and leave it
suspended for 2 minutes.
5) Once the test is completed, lower and release the
load as previously directed.
6)
Never use lifter that
has failed test.
Inspect the lifter for any stress damage, and repair or
replace components as necessary to successfully pass the
test.
7) Prepare a written report of the test and keep it on file.
Remote Control System Test
If the lifter has a Remote Control System, test it where the lifter is normally used. Use the
radio transmitter to activate each of the remote functions.
3
Vary the transmitter's direction
and distance from the lifter, to make sure transmissions are effective.
4
If the Remote Control System is not functioning correctly, ...
• the battery for the radio transmitter may need to be replaced, or;
• metal or other electrically conductive surfaces may be causing radio interference.
Reposition the transmitter to transmit signals effectively.
If the problem persists, vary the test conditions, to determine whether there is transmission
interference in the work environment or the Remote Control System is not functioning. Correct
any fault before using the Remote Control System.
1..... An equivalent simulation may also be used. Contact WPG for more information.
2..... A “qualified person” has successfully demonstrated the ability to solve problems relating to the subject matter and work, either by possessing a
recognized degree in an applicable field or a certificate of professional standing, or by possessing extensive knowledge, training and experience.
3..... Use a test material with appropriate “L
” (see page 14) to test the “attach” and “release” functions.
4..... This may require assistance from someone near the lifter, to verify functions are working as intended.
INSPECTIONS AND TESTS
Summary of Contents for MRTALP810CDC3O
Page 2: ...MRTALP8 DC3 35059 Rev 8 0 1 20 2 ...
Page 6: ...MRTALP8 DC3 35059 Rev 8 0 1 20 4 Note A standard MRTALP811LDC3 is shown SPECIFICATIONS ...
Page 11: ...Rev 8 0 1 20 MRTALP8 DC3 35059 9 TO CHANGE THE PAD FRAME CONFIGURATION ASSEMBLY ...
Page 47: ...Rev 8 0 1 20 MRTALP8 DC3 35059 45 ...
Page 48: ...MRTALP8 DC3 35059 Rev 8 0 1 20 46 ...
Page 49: ......
Page 50: ......