Rev 8.0/1-20
MRTALP8-DC3: #35059
39
C06
“Control head revision not
compatible”
1 chirp every
2 seconds
(none)
Incompatible version of software was installed or Intelli-
Grip® control unit has failed. Service is required.
C07
“Control head revision lockout”
continuous
(while button
is held)
(none)
Once “Power Save” mode is activated, “attach” and
“release” functions are prevented in connection with Code
C06. Service is required.
E00
E01
E02
E03
E04
“EEPROM error, cell #”
occasional
chirp
(none)
Memory error detected. Service is required.
I000
“I2C error (#)”
single chirp
(none)
Fault(s) detected in cable connecting to modular circuit
board. If code does not clear automatically , service is
required.
N00
“Automatic attach”
(none)
(none)
System activated “attach” mode as precaution because
significant vacuum was detected, even though no one
initiated “attach” function. No corrective action is
necessary.
N01
“Automatic attach”
(none)
(none)
System activated “attach” mode as precaution because
load did not release completely. No corrective action is
necessary.
N02
“Automatic attach”
(none)
(none)
System activated “attach” mode as precaution when lifter
was powered up because power was previously lost while
load was attached. No corrective action is necessary.
N03
“Unable to turn module power
off”
1 chirp every
2 seconds
(none)
Modular circuit board failed to power down. Remove 9V
battery. Disconnect connector between 12V battery and
vacuum generating system. Charge battery completely
(see “12-V
” on page 37). Then
reconnect battery and try to power down again.
If code persists, disconnect connector. Service is required.
N04
“Failed to turn controls power
off”
1 chirp every
2 seconds
(none)
Intelli-Grip® control unit failed to power down. Remove 9V
battery. Disconnect connector between 12V battery and
vacuum generating system. Charge battery completely
(see “12-V
” on page 37). Then
reconnect battery and try to power down again.
If code persists, disconnect connector. Service is required.
N05
“Unable to turn module power
on”
1 chirp every
2 seconds
(none)
Modular circuit board failed to power up. Charge 12V
battery (see “12-V
” on page 37). Then
power lifter up again. If code persists, service is required.
N06
“Power-down reminder”
2 chirps
on
briefly
Power down to prevent 12V battery discharge when lifter
is not in use.
N07
“Auto power-down disabled”
(none)
(none)
Automatic power-down is prevented. Power lifter down
and up again. If code persists, service is required.
N08
“powering down in # seconds”
1 chirp per
minute
(none)
Lifter will automatically power down in number of seconds
shown. Press any button to cancel action.
N10
“App-support hardware fault”
(none)
(none)
Fault is detected in hardware that enables communication
with mobile app. Power lifter down and up again. If code
persists, service is required.
Code
On-Screen Message
Buzzer
Pattern
Strobe
Light
Activity
Explanations/Directions
MAINTENANCE
Summary of Contents for MRTALP810CDC3O
Page 2: ...MRTALP8 DC3 35059 Rev 8 0 1 20 2 ...
Page 6: ...MRTALP8 DC3 35059 Rev 8 0 1 20 4 Note A standard MRTALP811LDC3 is shown SPECIFICATIONS ...
Page 11: ...Rev 8 0 1 20 MRTALP8 DC3 35059 9 TO CHANGE THE PAD FRAME CONFIGURATION ASSEMBLY ...
Page 47: ...Rev 8 0 1 20 MRTALP8 DC3 35059 45 ...
Page 48: ...MRTALP8 DC3 35059 Rev 8 0 1 20 46 ...
Page 49: ......
Page 50: ......