Rev 10.3/10-16
17
MTCL8FS10TDC: #35079
Sealing the Pads against the Load
The apply/release switch is located on the movable control pendant. The movable control
pendant allows the vacuum controls to be moved away from the lifter, so that the operator can
control airflow at a distance equal to the length of the pendant cord.
WARNING: Do not disconnect control pendant during lifter operation.
The movable control pendant is not intended to be disconnected during lifter operation.
Disconnecting the control pendant is likely to result in a load release and injury to the operator or
others nearby.
Turn the apply/release switch to the “apply” ( ) position (clockwise) to make sure the apply
function is activated.
WARNING: Keep apply/ release switch in “APPLY” position throughout lift.
Alternatively, if the lifter is equipped with a Remote Control System, press an apply button on
either the radio transmitter or the lifter, to make sure the apply function is activated.
This energizes the vacuum pumps, causing air to be drawn immediately at the vacuum pads.
The low vacuum warning buzzer also sounds an alarm until the lifter attains sufficient vacuum to
lift the maximum load weight (see T
O
L
IFT AND
M
OVE THE
L
OAD
: Load Capacity and Lift Light to
follow). Press the lifter onto the load until all the pads seal against it. The apply/release switch
must remain in the “apply” ( ) position throughout the entire lift.
Note: If a vacuum pad has been lying against a hard object (as during shipping), it may be
slightly distorted. Although initially it may be difficult to apply the pad to a load, this condition
should correct itself with continued use.
Reading the Vacuum Gauges
The lifter is equipped with 2 vacuum gauges, which indicate the current vacuum level in each
circuit of the lifter's vacuum system. The
green range indicates vacuum levels sufficient for
lifting the maximum load weight, whereas the
red range indicates vacuum levels that are not
sufficient for lifting the maximum load weight. The gauge needles should show a sudden surge
in vacuum as the vacuum pads seal against the load. If it takes more than 5 seconds for the
vacuum level to reach 5" Hg [-17 kPa] on a vacuum gauge, press on any pad that has not yet
sealed.
Summary of Contents for MTCL8FS10TDC
Page 2: ...View Quick Start Guide...
Page 40: ...Rev 10 3 10 16 38 MTCL8FS10TDC 35079...
Page 41: ...Rev 10 3 10 16 39 MTCL8FS10TDC 35079...
Page 42: ...Rev 10 3 10 16 40 MTCL8FS10TDC 35079...
Page 43: ...Rev 10 3 10 16 41 MTCL8FS10TDC 35079...
Page 44: ...Rev 10 3 10 16 42 MTCL8FS10TDC 35079...