Powering up the Lifter
1A
Press the lifter's power button ( — fig. 1A).
The vacuum pump will run for a few seconds,
as a normal function of the Intelli-Grip
®
self-
diagnostics.
The lifter automatically tests the 9-volt battery
for the notification buzzer each time the lifter
is powered up. When this battery runs down,
the LCD screen displays “Replace 9V battery?”
and the buzzer chirps once per minute.
Replace the battery as needed (see
).
Keep “attach” function
activated throughout lift.
Sealing the Pads on the Load
1B
Press the lifter’s “attach” button ( — fig. 1B).
The vacuum pump will run until the vacuum
pads seal completely. If the lifter takes too
long to attach, the notification buzzer chirps
and the LCD screen displays “Vacuum not
increasing normally”, along with a diagnostic code (see
). In
this case, press the lifter firmly against the load to help the pads begin to seal.
1
1..... Although a vacuum pad may become distorted during shipping or storage, this condition should correct itself with continued use.