Rev 4.0/2-21
P1-DC3: #35123AUS
35
V03A
V03B
“Pump running excessively”
1 chirp every
2 seconds
(none)
Vacuum pump is running more often than normal. Likely
causes include significant vacuum leak or difficulty
achieving minimum vacuum level due to high elevation.
In case of suspected leak, check for fault(s) in vacuum
system. See relevant topics in “ASSEMBLY,” “OPERATION”
“INSPECTIONS AND TESTS”, and “MAINTENANCE”.
In case of high elevation, contact WPG for directions.
V040
“Lockout (vacuum sensor error)”
continuous
(none)
Once “Power Save” mode is activated, “attach” and
“release” functions are prevented due to a vacuum sensor
malfunction. Make sure sensor connectors are attached
correctly.
V050
“DANGER! INSUFFICIENT
VACUUM!”
continuous
on
Vacuum levels in BOTH circuits are insufficient for lifting.
Keep everyone away from suspended load until it can be
safely lowered to a stable support.
Service is required.
V081
V082
V083
V084
“Sensor # error (low)”
(# indicates relevant vacuum
circuit)
continuous
in “attach”
mode;
(none)
Vacuum sensor malfunction in vacuum circuit indicated.
Make sure sensor connector is attached correctly.
1 chirp every
minute in
“power save”
mode
V091
V092
V093
V094
“Sensor # error (high)”
(# indicates relevant vacuum
circuit)
continuous
in “attach”
mode;
(none)
Vacuum sensor malfunction in vacuum circuit indicated.
Make sure sensor connector is attached correctly.
1 chirp every
minute in
“power save”
mode
Code
On-Screen Message
Buzzer
Pattern
Strobe
Light
Activity
Explanations/Directions
MAINTENANCE