background image

PZM

IV

 & PZMT

IV

World Precision instruments

9

* Electrodes, 
batteries and other 
consumable parts are 
warranted for 30 days 
only from the date on 
which the customer 
receives these items.

World Precision Instruments, Inc.

international trade center, 75 sarasota center Blvd., sarasota Fl 3440-958

tel: 94-37-003 • Fax: 94-377-548 • e-mail: sales@wpiinc.com

Order Toll-Free: 866-606-1974

 (in Florida, and all other calls, use 941-371-1003)

UK: 

Astonbury Farm Business centre • Aston, stevenage, Hertfordshire sG 7eG • tel: 0438-88005 • Fax: 0438-88006 • e-mail: wpiuk@wpi-europe.com

Germany: 

liegnitzer str. 5, d-0999 Berlin • tel: 030-688845 • Fax: 030-688670 • e-mail: wpide@wpi-europe.com

Warranty

WPi (World Precision instruments, inc.) warrants to the original purchaser that this equipment, including its 
components and parts, shall be free from defects in material and workmanship for a period of one year* from 
the date of receipt. WPi’s obligation under this warranty shall be limited to repair or replacement, at WPi’s 
option, of the equipment or defective components or parts upon receipt thereof f.o.b. WPi, sarasota, Florida 
u.s.A. return of a repaired instrument shall be f.o.b. sarasota.

the above warranty is contingent upon normal usage and does not cover products which have been 

modified without WPi’s approval or which have been subjected to unusual physical or electrical stress or on 
which the original identification marks have been removed or altered. the above warranty will not apply if 
adjustment, repair or parts replacement is required because of accident, neglect, misuse, failure of electric 
power, air conditioning, humidity control, or causes other than normal and ordinary usage.

to the extent that any of its equipment is furnished by a manufacturer other than WPi, the foregoing warranty 

shall be applicable only to the extent of the warranty furnished by such other manufacturer. this warranty will 
not apply to appearance terms, such as knobs, handles, dials or the like.

WPi makes no warranty of any kind, express or implied or statutory, including without limitation any 

warranties of merchantability and/or fitness for a particular purpose. WPi shall not be liable for any damages, 
whether direct, indirect, special or consequential arising from a failure of this product to operate in the manner 
desired by the user. WPi shall not be liable for any damage to data or property that may be caused directly or 
indirectly by use of this product.

Claims and Returns

• inspect all shipments upon receipt. missing cartons or obvious damage to cartons should be noted on the 
delivery receipt before signing. concealed loss or damage should be reported at once to the carrier and 
an inspection requested. All claims for shortage or damage must be made within 0 days after receipt of 
shipment. claims for lost shipments must be made within 30 days of invoice or other notification of shipment. 
Please save damaged or pilfered cartons until claim settles. in some instances, photographic documentation 
may be required. some items are time sensitive; WPi assumes no extended warranty or any liability for use 
beyond the date specified on the container.

• WPi cannot be held responsible for items damaged in shipment en route to us. Please enclose merchandise 
in its original shipping container to avoid damage from handling.  We recommend that you insure merchandise 
when shipping. the customer is responsible for paying shipping expenses including adequate insurance on 
all items returned.

• do not return any goods to WPi without obtaining prior approval and instructions (rmA#) from our returns 
department. Goods returned unauthorized or by collect freight may be refused. the rmA# must be clearly 
displayed on the outside of the box, or the package will not be accepted. Please contact the rmA department 
for a request form.

• Goods returned for repair must be reasonably clean and free of hazardous materials.

• A handling fee is charged for goods returned for exchange or credit. this fee may add up to 5% of the sale 
price depending on the condition of the item. Goods ordered in error are also subject to the handling fee.

• equipment which was built as a special order cannot be returned.

• Always refer to the rmA# when contacting WPi to obtain a status of your returned item.

• For any other issues regarding a claim or return, please contact the rmA department

Warning: This equipment is not designed or intended for use on humans.

Summary of Contents for PZMIV

Page 1: ...PZMIV PZMTIV Precision Zoom Stereo Microscopes INSTRUCTION MANUAL Serial No _____________________ 072105 World Precision Instruments www wpiinc com ...

Page 2: ...TIV System Diagram 4 Specifications 5 Operation 6 Maintenance 7 Appendix Boom Stand Assembly 8 Warranty 9 Copyright 2004 by World Precision Instruments Inc All rights reserved No part of this publication may be reproduced or translated into any language in any form without prior written permission of World Precision Instruments Inc ...

Page 3: ... optics provide image sharpness found only among the best of this class PZMIV uses modular parallel beam path design and a high quality optical system The advanced optical design with plan achromatic objectives provides sharp and distortion free image throughout the entire zoom range The ergonomic design makes it easy to use zooming is smooth and effortless controlled by a large spring loaded knob...

Page 4: ...nd 3 Mount the microscope head into the focus mount 4 Remove the protective cap on the bottom of the microscope head 5 Refer to the parts diagram on page 3 and follow the set up instructions below 6 Install the WFH 10x eyepiece pair 1 included The paired eyeguards can now be attached to the eyepieces 7 The exact working distance is found by adjusting the focusing knob 7 8 When the optional stands ...

Page 5: ...etent control to provide discreet zoom stops or continuous zooming 4 Magnification Knob 5 Body Rotation Clamp Locking Screw 6 Stage Plate 7 Focusing Knob 8 Track 9 Base PZMTIV only 10 CCD Color Video Camera optional 11 C Mount CCD Camera Coupler optional 12 Video Photo Port 13 Light Path Selector Bar when out light to the right eyepiece is switched to the photo port 10 11 Fig 1 1 2 3 8 9 7 4 5 6 1...

Page 6: ...02003 Objectives 0 32x 502016 0 5x 502017 0 63x 502018 1 0x 502019 Eyepieces 10x 502010 16x 502011 20x 502012 25x 502013 Digital camera with integrated lens filter thread of 28 37 or 43 mm Digital Camera Adapter Kit 501384 Video Camera COLCAM CCD Coupler 0 3x 500261 0 5x 500262 0 75x 500263 Ring Light Adapter 502015 Pixera VCS 10132 Track Stand 502002 Binocular Body 502000 Trinocular Body 502001 I...

Page 7: ...ves 10x Eyepiece 16x Eyepiece 20x Eyepiece 25x Eyepiece Objective Mag Field mm Video Field Mag Field mm Video Field Mag Field mm Video Field Mag Field mm Video Field Working Distance 0 32x 1 9x 16x 106 13 1 49 8 6 1 3 2x 25 6x 70 6 8 8 49 8 6 1 3 9x 32x 55 4 6 9 49 8 6 1 5x 40x 45 4 5 6 49 8 6 1 296 mm 0 5x 3 1x 25x 67 7 8 4 31 8 3 95 5x 40x 45 2 5 6 31 8 3 95 6 2x 50x 35 5 4 4 31 8 3 95 7 8x 62 8...

Page 8: ...y zoom out to lower magnification by adjusting magnification knob 4 while remaining in focus 4 Diopter Adjustment If image does go out of focus when zooming out zoom to the lowest setting and focus each eyepiece individually by adjusting the diopter adjustment ring 2 5 Video Photo Applications Slide the light path selector bar 13 to the PHOTO IN position in order to direct the light to the video p...

Page 9: ...t spray If stains deposit on exterior surfaces of the lenses clean them gently using a mild soap solution with a lint free cloth Industrial solvents should not be used since they may penetrate to the inside of the lens components and dissolve the lens cement When cleaning and lubricating the mechanical parts special attention must be taken not to stain the optical surfaces with grease The moveable...

Page 10: ...st 4 Insert Horizontal Bar into opening in cross block slot side facing up Two different types of focusing assemblies are available E arm 1 Remove E arm from protective packaging 2 Insert E arm into the end of the Horizontal Bar secure by tightening set screw 3 Tighten one or both hex screws 2 5 mm and 4 mm so the microscope head is tiltable but not free to swing Tips E arm can be inserted from th...

Page 11: ... or fitness for a particular purpose WPI shall not be liable for any damages whether direct indirect special or consequential arising from a failure of this product to operate in the manner desired by the user WPI shall not be liable for any damage to data or property that may be caused directly or indirectly by use of this product Claims and Returns Inspect all shipments upon receipt Missing cart...

Reviews: