Changing the Battery Type Setting
The standard setting for the onboard battery charger
is Flooded/AGM. EXCEPTION: If your machine was
ordered from NSS equipped with Gel batteries, then
the charger was configured for Gel batteries at the
factory.
Configuring the Charger for Gel batteries:
1. Remove the top cover.
2. Pull the jumper off the board (position 1), and
then store the jumper for later use at position 2.
See photo below.
3. Reinstall the top cover.
Configure the Charger for Flooded/AGM batteries
1. Remove the top cover
2. Pull the jumper from the storage location (position
2), and install the jumper at position 1.
3. Reinstall the top cover.
Operating the Battery Charger
CAUTION: DIFFERENT BATTERY TYPES HAVE
DIFFERENT CHARGING REQUIREMENTS.
FAILURE TO PROPERLY IDENTIFY YOUR
BATTERY TYPE, AND SET THE CHARGER
Position 1
Remove
jumper for gel
Position 2
Storage Location
For jumper
Top cover
screws
Summary of Contents for 2016 AB