Fault Conditions
PMMK Software F04100
8 - 9
M-032170
BREAK-
THROUGH
HIGH LIMIT
This is only used
when using the
Breakthrough func-
tion in a welding
sequence and the
ontime level is above
the breakthrough limit
before blanking time
is over.
Breakthrough limit is set to
high. Too much sealer used
on the part which would bring
the ontime above the break-
through level.
Check that proper sealer was
used, check limis for break-
through function
Message
Explanation
Possible Cause
Remedy