MedWeld 5000 Overview
MedWeld 5000 Technical Reference Manual
1 - 7
M-032170
Control Transformer
The control transformer receives the supply voltage (480, 415 or 380
VAC at 50 Hz or 60 Hz) from the circuit breaker. It reduces the supply
voltage to the level required for other devices. It has step-down taps for
•
120 VAC outputs and
•
Low-voltage (24 VAC) “clean” power to the electronics power
input of the inverter regulator board.
MFDC Inverter
The MFDC inverter assembly consists of a regulator board, the charging
pack, discharge resistors, capacitors and IGBTs (insulated gate bipolar
transistors). The IGBTs control the time that current is allowed to pass
to the welding transformer.
The regulator board receives the gating signal from the timer unit and
translates the signal into target flux or current (depending on firing
mode). The regulator gates the IGBTs and monitors to obtain the target.
The charging pack is described above. The discharge resistors discharge
the capacitors.
•
The capacitors smooth the VDC bus and provide energy during the
weld.
•
The IGBTs are electronic switches that control when power is
supplied to the welding transformer.
•
Inverters have at least one thermal switch that monitors
temperature. The inverter will stop gating if a thermal switch is
tripped.
•
The inverter provides the outputs to the welding transformer at H1
and H2.
Timer Unit
When the MedWeld 5000 timer unit receives a START WELD
command, the timer unit starts executing the selected weld sequence.
When the DC bus voltage stabilizes, the inverter is ready to weld. The
inverter activates the IRTW signal, and the timer unit is capable of
sending gating signals to the inverter. The inverter performs the power
conversion to provide DC current to the welding transformer.
At the end of the weld sequence, the timer unit drops out the isolation
contactor for the weld transformer.
NOTE:
If the weld control provides the weld transformer isolation contactor, the
inverter remains activated and is de-activated only by inverter fault
conditions or power-down of the weld control. Refer to the drawings
provided with your system for more information.
The timer unit indicates any fault conditions detected at the inverter,
either at the data entry panel, or at another MedLAN device connected
to the timer unit. (This can be the WebVIEW.)
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...