MedWeld 5000 Technical Reference Manual
2 - 1
M-032170
Installing the MedWeld 5000
2
To install the MedWeld 5000, you must provide the required DeviceNet
communications, configure the unit for the MedLAN network, set the
network address and program the timer unit to meet your application
requirements.
These steps are described in the sections that follow.
Getting Started
Making the Required
Connections
To install the MedWeld 5000, follow these steps:
1. Make certain the circuit breaker handle on the enclosure is in the
OFF (down) position before attempting to open the door.
WARNING!
WARNING! The cabinet door is interlocked with
the circuit breaker to prevent opening the door
while power is applied. DO NOT attempt to force
open the door. Damage to the cabinet may
result. NEVER attempt to defeat the interlock.
2. Inspect the inside of the enclosure for any damage caused in
shipping. Check for any parts which may have come loose in
shipping, any packing materials or loose connections.
3. Place the enclosure in the desired location. Secure it with the
mounting tabs and holes provided. The cabinet is designed to be
mounted using all four of the mounting tabs.