Installing the MedWeld 5000
MedWeld 5000 Technical Reference Manual
2 - 5
M-032170
Caution:
The MedWeld 5000 address is the same as the
DeviceNet node address. If the port address is changed
in the network settings, DeviceNet node address will be
changed to match the port address and vise versa.
Use the WTC DEP-100S to program the MedLAN address for each
individual weld control, through the top (DEP) port of the timer unit.
NOTE:
The steps required to set the address are listed below. Refer to the
manual provided with the DEP-100S programming device for more
information on operation.
To set the addresses for each weld control, follow this procedure:
1. Plug the DEP-100S into the DEP port on the timer unit (or the DEP
port on the enclosure door, if provided).
2. Press the key labeled PROGRAM MODE on the DEP-100S.
3. Press F5 on the DEP-100S (for additional functions).
4. Press F4 to select network addressing (NETWORK ADDR).
Press the F1 key to select the port # (MedLAN address).
With the numeric keys, enter an address (“port”) number (00–29).
Press ENTER to tell the DEP-100S you have completed your selection.
Press the F3 (download) to send the new MedLAN address to the
device. (A message that the download was completed will appear
briefly.)
Unplug the DEP-100S and move to the next control. Follow this
procedure for every control in the network.
Caution:
Make certain that each device has a unique address.
Duplicate addresses may cause the network to lock up.
Programming the
Timer Unit
Each timer unit provides flexible I/O for defining weld schedules. It also
lets you configure the device to meet your application requirements by
programming setup parameters. The control provides programmable
steppers to compensate for lost current density over the life of the
electrodes.
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...