Communications and I/O
3 - 2
MedWeld 5000 Technical Reference Manual
M-032170
ISOLATION CONTACTOR Input
This is an input to the weld control enclosure, showing whether the
isolation contactor is open or closed. It is normally open.
If this contact fails to change states after a valid schedule is initiated, the
control will generate a ISO-CNTR OFF WHEN NEEDED fault
condition.
If this contact fails to return to its original state after the contactor is
turned off (including the Isolation Contactor Delay), the control will
generate an ISO-CNTR ERR BKR TRIPPED fault condition. It will
also de-energize the NO FAULT output and trip the circuit breaker.
THERMAL SWITCH Input
This input to the timer unit indicates that the weld enclosure has reached
an over-temperature condition.
If this input is not active when the control receives the signal to initiate a
weld, the timer unit completes the schedule in No Weld, generates a
SYSTEM COOLING fault and de-energizes the NO FAULT output (to
indicate an active fault condition).
Local Outputs
NO FAULT Output
This output is ON to indicate that the control is functioning normally. If
the control shuts down as the result of a fault condition, this output will
be turned OFF.
ALERT Output
This output is OFF to indicate that the control is functioning normally.
Alert conditions are usually less serious than faults and are normally
used to warn the operator that maintenance is required.
ISOLATION CONTACTOR Output
The ISOLATION CONTACTOR output operates the weld transformer
isolation contactor. Output #12 on the SLC output module informs the
MFDC inverter when it is required to pull in the charging pack.
The charging pack remains energized. It will drop out only when an
inverter fault is generated, or during an emergency stop condition.
SHUNT TRIP Output
Activating this output trips the circuit breaker in case of a catastrophic
failure.
INITIATE ACKNOWLEDGE Output
This output indicates that a schedule is being executed by the timer unit.
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...