Communications and I/O
MedWeld 5000 Technical Reference Manual
3 - 9
M-032170
WELD/NO WELD Output
When the WELD/NO WELD input is opened, it energizes this
output (to indicate that the control is in No Weld Mode). If a valid
weld initiate is received while the control is in No Weld Mode, the
weld schedule will schedule normally, BUT WELD CURRENT
WILL NOT FLOW.
FAULT Output
This output is normally OFF, indicating that the control is
functioning normally. If the control shuts down as the result of a
fault condition, this output will be turned ON.
NO FAULT Output
Certain applications use the NO FAULT output (rather than the
FAULT output above). This output is normally ON (to indicate that
no fault conditions exist). If the control shuts down as the result of a
fault condition, this output will be turned OFF.
NO ALERT Output
This output is normally ON. It turns OFF to indicate an alert
condition. Alert conditions are usually less serious than faults and
normally serve to warn the operator that maintenance is required.
ALERT Output
This output is normally OFF and turns on to indicate an alert
condition. Alert conditions are usually less serious than faults and
are normally used to warn the operator that maintenance is
required.
INITIATE ACKNOWLEDGE Output
This output indicates that the control is executing a schedule.
END OF STEPPER Output
The control will activate this output when the stepper completes the
last weld in the last step.
This output becomes active when one or more linear steppers has
reached the end of its program or one or more SureWeld steppers
has reached its programmed limit.
WELD IN PROGRESS Output
The control turns this output ON and OFF in response to the output
control function.
WELD COMPLETE Output
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...