Weld Schedules
MedWeld 5000 Technical Reference Manual
4 - 9
M-032170
NOTE:
The weld data generated by the control (and displayed at the DEP or a
data monitoring device) does NOT include every function that provides
weld current. Keep this in mind when programming a weld schedule.
Only the following functions are included in the Weld Data display:
Weld Functions
Using Automatic
Voltage
Compensation
20
WELD nn CY/IMP mm %I *
21
TEMPER nn CY/IMP mm %I
22
PREHEAT nn CY/IMP mm %I
23
POSTHEAT nn CY/IMP mm %I
24
PRE-WELD nn CY/IMP mm %I
26
WELD nnnn MSEC mm %I *
* The stepper is active during this function.
NOTE:
When Function
IMPULSE= nn HEAT CY, nn COOL CY (nn=1-99)
appears before any weld function in a schedule, the control displays IMP
(impulses) rather than CY (cycles) to indicate the weld control will
pulsation weld.
Time (Cycles)
99%
20%
%I
20 cycles
60%I
WELD 20 CY 60%I