Stepper Data
MedWeld 5000 Technical Reference Manual
7 - 3
M-032170
When programming Aux. Counter Max Counts to 00000, the output is
the same as the STEPPER ALERT / APPROACHING MAXIMUM
output. Setting the AUX. COUNTER RESET input HIGH resets all of
the steppers’ auxiliary weld counters. The existing STEPPER RESET
and TIP DRESS RESET inputs will also reset the counters.
You can view and modify the stepper’s auxiliary weld count. It is
available on the Stepper Status display of the DEP-100S (Hand-Held
Terminal).
Default Linear
Stepper Profile
As shipped from the factory, the linear steppers use this profile by
default:
START OF STEPPER
STEP #1 00 %i 0700 AMPS IN 0060 WELDS
STEP #2 00 %i 0700 AMPS IN 0180 WELDS
STEP #3 00 %i 0700 AMPS IN 0300 WELDS
STEP #4 00 %i 0700 AMPS IN 0600 WELDS
STEP #5 00 %i 0700 AMPS IN 0800 WELDS
STEPPER GROUP #00
END OF STEPPER
Use one of the programming methods DEP-100S, or WebView to
change the stepper profile to the values required by your application.
STEPPER APPROACHING MAX.
(FAULT)
(ALERT)
(NONE)
When a weld sequence is assigned to a linear stepper, this fault indicates
that the stepper has started the final step of the assigned stepper.
END OF STEPPER (FAULT)
(ALERT)(NONE)
This fault is generated when the stepper has completed the number of
welds specified in the last step, the control resets the count to zero and
generates an END OF STEPPER fault.
Summary of Contents for MedWeld 5000
Page 2: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06 M 032170...
Page 6: ...MedWeld 5000 Technical Reference Manual Modified 1 31 06...
Page 38: ...Installing the MedWeld 5000 2 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 82: ...Advanced Software Features 5 12 MedWeld 5000 Technical Reference Manual M 032170...
Page 120: ...Hardware Troubleshooting 9 10 MedWeld 5000 Technical Reference Manual M 032170...