Up
Down
XON/XOFF
Down
Up
Both
Up
Up
None
* = Factory Setting
4.2.3. Default Response Message Format (Sw6)
When commands are invoked, the CMS can respond with either verbose (English text) or terse
(numeric / abbreviated) messages. Response messages are summarized in
Section 10.2
. After
installation, the /P command can also set the response format to "none" (Quiet Mode). When
Quiet Mode is selected, the unit will not send response messages.
Switch 6 Default Response Message Type
Down
Verbose (English Text) *
Up
Terse (abbreviated / numeric)
* = Factory Setting
4.2.4. Default Command Echo (Sw7)
Switch Seven enables or disables the Command Echo. When enabled, characters sent to the
CMS will be echoed back to the control device.
Switch 7
Default Command Echo
Down
Enable*
Up
Disable
* = Factory Setting
4.3. Initialize Unit to Default Settings
If Option Switch settings are changed, new parameters will not take effect until the CMS is
initialized.
Caution:
After initialization, the CMS will revert to the parameters specified
by the Option Switches. Any command-selected parameters will be lost.
Simultaneously press the SET and CLEAR buttons, located on the face of the CMS.
1.
Release the CLEAR button, wait for the Port LEDs to flash, and then release the SET
button.
2.