Cleaning Air Box
Installation
ba75731e04
12/2013
3 - 5
3.5.2 Connecting the wires
Materials
required
Wire end sleeves, suitable for the connecting wires, with suitable crimping
tool
Tools
Cable stripping knife
Wire stripper
Small screw driver
Fig. 3-2
Electrical connection
3
Open the enclosure of the Cleaning Air Box.
4
Feed the power cable into the enclosure through the right-hand cable
gland.
5
Feed the control line into the enclosure through the second cable gland
from the right.
6
Connect all wires to the terminal strip. While doing so, pay attention to
the specifications on the label located on the right side of the terminal
strip.
7
Close the enclosure of the Cleaning Air Box.
Control
line
Power
cable
5 R2
R1
xxx
V A
C
L
N
4
3
2
1
5 R2
R1
xxx
V A
C
L
N
4
3
2
1