4 - 2
ba75731e04
12/2013
Operation
Cleaning Air Box
4.2
Actions against the formation of condensate and icing
During very damp weather, moisture can condensate, gather and, at tempera-
tures below 0°C, freeze in the hose system and pump. This can possibly affect
the pumping capacity.
With outside temperatures around and below the freezing point, check the hose
system for water or ice in the lines.
To prevent the icing of the pump, you can shorten the stoppage and/or extend
the cleaning duration. Due to the lower ratio of stoppages and cleaning dura-
tions, the generation of heat during operation is often enough to prevent the
formation of ice in the pump.
NOTE
When installing the compressed air hose make sure that no water possibly re-
maining in the hose can enter the Cleaning Air Box.