Pin(s) - Signal Name (Continued)
28 - AUX +5 VDC (OPTIONAL)
This optional output can be used to power external auxiliary equipment. A
jumper must be installed on the system interface board to activate this output.
Total load for this output cannot exceed 200 mA. In addition, the combined
external load of +15V, -15V and +5V outputs cannot exceed 11.5 Watts.
62 - AUX GND
This is a C-5000 power ground connection suitable for electrical reference
ground to other auxiliary equipment.
32 - SYSTEM DIRECT
This pin, when grounded, will place the attached RT-5000 into Direct mode.
52 - AUX MIC PTT
This pin, when grounded, will activate the PTT of the active RT.
57 - TP11
This pin provides a test point for adjusting the RT-X WB XMT AUDIO OUT
amplitude