DOM-XP 

 
 

4-channel weekly timer and telecontrol unit 

 

Page 2 of 4 

Subject to technical modifications 

DOM-XP_V2.10_PI_2019-04_EN 

 

Writing conventions 

CAUTION

 

Avoid the described hazard: Otherwise 

minor

 or 

medium

 bodily injury or 

property damage will result. 

 

WARNING

 

Avoid the described hazard: Otherwise there is danger from 

electric voltage

 

that can lead to death or 

serious

 bodily injury. 

 

For your safety 

For safe operation and to avoid personal injury and equipment damage through operator error, always 
read these instructions, become familiar with the device, and follow all safety instructions on the 
product and in this document, as well as the safety guidelines of Wurm GmbH & Co. KG Elektronische 
Systeme. Keep these instructions ready to hand for quick reference and pass them on with the device 
if the product is sold. 
Wurm GmbH & Co. KG Elektronische Systeme accepts no liability in case of improper use or use for 
other than the intended purpose. 

Target group 

These instructions are intended for "service technicians". 

Intended use 

The device is a 4-channel weekly timer and telecontrol unit. 

 

 

WARNING 
Danger to life from electric shock and/or fire! 

 

Switch off the power to the entire plant when carrying out installation, wiring or removal 
work. Otherwise a mains voltage and/or external voltage may still be present even if the 
control voltage is switched off. Always remove both power plugs (L and N). 

 

Only qualified electricians are permitted to wire the device. 

 

Use only the correct tools for all work. 

 

Check all wiring after connection. 

 

Take note of the maximum loads on all connections. 

 

Never expose the device to moisture, for example due to condensation or cleaning 
agents. 

 

Take the device out of operation if it is faulty or damaged and is therefore compromising 
safe operation. 

 

Do not open the device. 

 

Do not attempt to repair the device yourself. If the device requires repairs, send it in with 
an exact description of the fault. 

 

CAUTION 
Electromagnetic interference can cause faults! 

 

Always use shielded data cables and place them far away from power lines. 

 

 

 

Wurm Infocenter 

 

paperless info 

 

 

Software revisions and validity of documentation 

Software version   

V2.10  2019-04 

Documentation status 

Any software versions not listed are special solutions for individual projects and are not described in detail in this 
document. This document automatically ceases to be valid if a new technical description is issued. 

Manufacturer: 

Wurm GmbH & Co. KG Elektronische Systeme, Morsbachtalstraße 30, D-42857 Remscheid 

For further information, see our website at 

www.wurm.de

 

 
 
 
 

Summary of Contents for DOM-XP

Page 1: ...angeover Delay times per channel Restoring of the logic switching state after a power failure Manual operation of the channels through digital inputs Documentation of the 4 digital inputs Simple parameter settings Display of relay states Parameter setting through plain text menu and direct operation Plug in screw terminals Clear text designation of switching outputs and digital inputs in FRIGODATA...

Page 2: ...ntire plant when carrying out installation wiring or removal work Otherwise a mains voltage and or external voltage may still be present even if the control voltage is switched off Always remove both power plugs L and N Only qualified electricians are permitted to wire the device Use only the correct tools for all work Check all wiring after connection Take note of the maximum loads on all connect...

Page 3: ...fire Switch off the power to the entire plant when carrying out installation wiring or removal work Otherwise a mains voltage and or external voltage may still be present even if the control voltage is switched off Always remove both power plugs L and N This device is designed for top hat rail installation The housing is of a standard size and is also suitable for installation in fuse boxes and di...

Page 4: ...to 100m 0 75mm Up to 400m 1 5mm Technical data Power supply 230V 10 15 approx 5VA Digital inputs 4 x potential free contact for documentation only Internal power supply 12V Output relay 4 x switching output normally open contact rated voltage 230V 4 2 A Central unit Single chip microcomputer data memory and quartz clock with 5000h power reserve Monitoring system Self monitoring of data memory and ...

Reviews: