13
of connecting cable with wire feeder, and ensure the tight connection.
• Connect the joint of 6-core control cable with welding machine and wire feeder respectively.
Connection gas supply
• Gas regulator in the attached accessories is installed and screwed firmly on the bottle to prevent air leak.
• Connect and firmly screw the two core plug of heater cable on the gas regulator to “Heater Socket” on the
rear board of welder.
• Connect the one end of gas hose in the attached accessories with the outlet of gas regulator and firmly hold
with hoop also in the attached accessories, the other end to “Gas Inlet” (gas valve joint) on the back of
wire feeder device.
Connection work piece
Connect quick connector (male) of earth cable to the “-“ socket on the front panel of welding machine, and
twist the quick connector (male) clockwise to ensure the tight connection. The other end clamps work piece.
Connection of cables
• For solid wire, connect wire feeder to the “+” output of machine, connect earth cable to “-“output of
machine.
• For flux core wire, connect wire feeder to the “-“output of machine, connect earth cable to “+” output of
machine.
Commissioning
• Check all connections and make sure all connections and earth are correct before switching on machine.
• Switch on machine, set gas checking switch to “Gas checking”, adjust gas regulator to get required gas
flow, then put gas checking switch to “Welding”.
• Press inching switch on the wire feeder or torch trigger, feed the wire the top end of torch.
• Test welding, adjust the knobs to set welding current adjustment, welding voltage adjustment knob, arc
ending current adjustment, arc ending voltage adjustment knob.
WANING:
iron plate and other bad conductor can not be used to connect machine to work piece.