2.  Technical Data

•  Maximum operating pressure 10 bar (150 psi)

•  Operating pressure 2 bar

•  Air consumption 350 Nl/min

•  Spray distance 13 - 17 (21) cm

•  Weight incl. cup: 612 g

3.  Scope of Delivery

•  Spray gun with 1.7 nozzle

•  0.6 liter PVC cup with integrated anti-drip device

•  Continuous round/flat spray control

•  Universal spanner

•  Allen key width 4 mm

•  Quick coupling nipple

4.  Functional Description

The Würth AP HVLP is a universal and handy spray gun with adjustable 

round/flat fan for primers and fillers with a viscosity of 22-40 sec. meas-

ured with the  DIN 4 viscosity cup. The spray gun body is made of forged 

aluminium and anodised. Materials containing abrasives, acid or benzine 

may not be used. The compressed air required for spraying is fed at the 

air inlet integrated into the gun handle. By pulling the trigger until the first 

pressure point, the air valve is opened (pre air control). When pulling the 

trigger further, the paint needle is pulled out of the paint nozzle. The mate-

rial flows out of the paint nozzle and is atomised by the compressed air 

simultaneously streaming from the air cap. The lid is equipped with an anti 

drip device preventing material flow from the ventilation hole.

5.  Safety Instructions

Warning! Attention!

Prior to putting the unit/paint spray gun into operation, read the operat-

ing instructions completely and thoroughly. The stipulations contained 

therein are to be respected in any case. After that, the operating in-

structions are to be stored in a safe place, accessible for every user of 

the equipment.
The unit/paint spray gun may only be put into operation by persons 

familiar with its use (professionals). Inappropriate use of the unit/paint 

spray gun, modification of any kind or combination with inappropriate 

other parts may cause material damage, serious hazard to the user‘s, 

other person‘s or animal‘s health or even death.
Würth shall not take any responsibility for such damages (e. g. failure 

to respect the stipulations laid out in the operating instructions).
The applicable safety, workplace and worker health protection regu-

lations of the respective country or area/district in which the system/

the paint spray gun is used are to be respected in any case (e. g. the 

German Rules for the Prevention of Accidents BGR 500 (BGV D25) 

and BGV D24 issued by the Central Office of the Professional Trade 

Associations, etc.).

Please note:

Never point paint guns at yourself, at other persons or animals. Sol-

vents and diluting agents can cause burns. Only the respective quanti-

ties of solvents and paints required for work progress may be present 

in the direct surroundings of the unit and are to be returned after work 

to their assigned storage rooms. Before any repair work may be carried 

out, the unit must be disconnected from the compressed air network 

and pressure must be released.

Before starting to use the paint gun, particularly after repairs, en-

sure that screws and nuts are correctly tightened, and check that 

gun and hoses do not leak.

Defect components must be replaced or repaired, use original spare 

parts only.
No  sources  of  ignition  (e.g.  open  flames,  burning  cigarettes,  lamps 

without ex-protection etc.) may be present during painting, as easily 

flammable mixtures are generated during the painting process.
Occupational safety regulations must be applied when painting (res-

piratory protection etc.). Appropriate ear protection muffs are required, 

as a sound level of 90 dB (A) can be exceeded when painting under 

higher pressure levels.
No vibration is transmitted to the upper parts of the operator’s body 

during the painting process.

Recoil forces are negligible.

The use of this product in explosion hazard areas Zone 0 is pro-

hibited.

Warning! Attention!

6.  Use
6.1. General

Before putting into operation, and especially after each cleaning and any 

repair work, check to see that all screws and nuts are tight. This applies 

in particular for the material flow control screw (counter nut), the round/

flat spray control as well as the hexagon screw, for the air micrometer. For 

servicing/repair work of any kind the system must be devoid of pressure, 

i.e. disconnected from the air supply. Failure to respect this safety warn-

ing may result in damage and injuries, even death at worst. Würth does 

not take any responsibility for possible results of such failure.

a)  Mount the nozzle set tightly (use universal wrench for the paint noz-

zle). Align the air nozzle so that the number stamped into it can be 

read from the front the right way round.

b)  Blow out the air hose before attaching it to the air connection (G ¼ 

ext.). The air hose must be pressure-resistant for min. 10 bars and 

solvent-resistant. Total electric resistance: < 100 million Ohm, for 

example Würth air hose.

6.2. Setting the Spray Pattern

The spray pattern can be set steplessly within the range of the preset air 

nozzle setting up to a round spray by means of the round and flat spray 

control.

6.3. Reduction of the Material Volume

The material flow and the needle lifting can steplessly be reduced if the 

material flow control is screwed loose.

6.4. Changing the Nozzle Set

A bad spray pattern increases the working time for grinding work. 

Therefore change the complete nozzle set (air cap, paint nozzle and paint 

needle) in time.

6.5. Exchanging the air piston and air 

piston packing

To replace the air piston remove the air micrometer. Pull out spring and air 

piston. Exchange the air piston. Unscrew stuffing box screw and remove 

the old packing. Now insert new packing with flat end first and gently 

tighten stuffing box screw towards packing, then mount air piston with 

spring and air micrometer and fully tighten until easy movement of the air 

piston rod is achieved.

6.6. Adjusting the air volume by means of 

the air micrometer

The infinitely variable air micrometer allows the spray air volume to be 

adapted to suit the medium being sprayed or misted.

Notice!

Maximum atomization = Air micrometer in vertical position (parallel to 

gun body)
Minimum atomization = Air micrometer in horizontal position (across gun 

body)

Warning! Attention!

While the spray gun is connected to the air supply, the air micrometer fix-

ing screw, must not be removed. When the fixing screw is removed, the 

spray gun must not be put into operation.

6.7. Replacement of the self adjusting 

paint needle packing

For replacement of the self-adjusting paint needle packing the paint 

needle must be removed. Insert hollow key SW 4 with its cylindrical con-

nection into the gun instead of the paint needle, and unscrew the packing 

screw from the gun, together with compression spring and packing.Push 

compression screw, compression spring and new packing  onto cylindri-

cal connection of the hollow key, and screw them tight inside the gun 

body. Check paint needle for damage and reassemble.

Betriebsanleitung Wuerth AP HVLP.indd   4

22.02.2012   13:41:51

Summary of Contents for AP HVLP

Page 1: ...ien 8 D pannage 9 Conditions de garantie 10 Pi ces de rechange Art Nr Order No R f No 0891 700 07 1 8 1 7 1 Aufbau 1 1 Luftkolben nicht sichtbar 1 2 Stopfbuchse f r Luftkolben 1 3 Abzugb gel 1 4 Farbn...

Page 2: ...lldruckpegel von 90 dB A berschritten wird ist ein geeigneter Geh rschutz zu tragen Bei Anwendung der Lackierpistole werden keine Vibrationen auf die oberen K rperteile des Bedieners bertragen Die R c...

Page 3: ...tnachstellende Nadelabdichtung de fekt D sensatz verun reinigt oder besch digt Material nachf llen Teile entsprechend anziehen Teile reinigen oder auswechseln Luftverteilerring defekt Luftverteilerrin...

Page 4: ...pplied when painting res piratory protection etc Appropriate ear protection muffs are required as a sound level of 90 dB A can be exceeded when painting under higher pressure levels No vibration is tr...

Page 5: ...degrees If defective pattern remains clean fluid tip pin and air circuit Paint spray flutters Too little material in cup fluid nozzle not tight self adjusting needle sealing dam aged nozzle set dirty...

Page 6: ...tc Un casque de protection auditive ad quat doit tre utilis puisque le niveau sonore de 90 dB A est d pass lors du pistolage des pres sions plus lev es L utilisation d un pistolet de mise en peinture...

Page 7: ...ne de la buse de peinture et le cercle d air Anneau de distribution d air d fectueux Remplacer l anneau de distribution d air D faut Cause Solutions Jet vibre Pas assez de produit dans le r cipient bu...

Page 8: ...9 Repair kit 10 Pi ces de rechange R f D signation 0891700015 Paquet de tamis de peinture 0818700210 Godet gravit en plastique 0 6 l 0891700071 Kit projecteur 1 4 0891700072 Kit projecteur 1 7 0891700...

Reviews: