15
Therefore never hold your hand in front of the
air-intake opening 1 as this can lead to malfunc-
tions!
4. Pull the trigger
8
. The gas mixture is ignited elec-
trically and the fastening bolt/nail is driven into
the structural material.
Note:
Firing can only take place when the
neck-down sleeve
14
is pressed in
completely
and
when
at least 3
bolts/nails are in the magazine
9
.
5. Release the trigger
8
and lift off the tool. The ex-
haust gas is expelled via the exhaust outlet
7
. At
the same time fresh air is blown into the combus-
tion space.
Note:
When no further bolt/nail is fired, the blower
will continue to run for approx. 10 seconds and then
switches off.
The tool is designed for continuous operation.
In the process, the neck-on sleeve can get
very hot. In case of visible defects of the tool,
stop working with the tool immediately and
forward it to Würth for repair.
Clearing a Jam
It is possible that a fastening bolt/nail gets stuck in
the discharge channel and causes a jam. In this ca-
se, stop the work and correct the jam.
1. Remove the battery and the gas cartridge.
2. Remove the magazine strip.
3. Disengage the locking
fixture
3
and pivot the
holding plate
21
up-
ward.
Clear the jam.
4. Reinsert the holding
plate again and enga-
ge the lock.
Maintenance and Cleaning
For proper and secure operation, the following tool
maintenance must be performed regularly:
Cleaning the Filter Mat
For high dust contamination, the filter mat must be
cleaned after each work day.
Open the lid
1
and take out the filter mat. Clean the
filter mat with compressed air or replace it when
heavily contaminated.
Cleaning the Discharge Channel and
Magazine
To reduce the danger of jams and to avoid increa-
sed wear, regularly clean the discharge channel, the
neck-down sleeve and the guide rail in the maga-
zine with compressed air.
Do not oil the movable
parts.
Cleaning the Housing
Clean the housing with a clean, dry cloth. For cleaning
and care, we recommend Würth plastic cleaner and
Würth maintenance products for plastics. Remove
heavy dust contamination with compressed air.
If the machine should happen to fail despite the care
taken in manufacture and testing, repair should be
carried out by an authorized customer service agent
for Würth power tools.
For all correspondence and spare parts orders,
always include the article number on the type plate
of the machine.
For the current spare parts list of this machine, log
into the Internet under “http://www.wuerth.com/
partsmanager” or ask for a copy at your nearest
Würth branch office.
3
21