background image

12

Tool Specifications

Compressor 

K 210

K 290

K 410

Article number 

0701 221

0701 229

0701 241

Intake air quantity

185 l/min

284 l/min

366 l/min

Effective delivery quantity 

105 l/min

152 l/min

180 l/min

Rated input

1.5 kW

2.2 kW

2.2 kW

No-load speed

2850 min

-1

2850 min

-1

2850 min

-1

Oil quantity

0.2 l

0.35 l

0.44 l

Oil type

ISO 100

ISO 100

ISO 100

Rated voltage

230 V

230 V

230 V

Insulation class

F

F

F

Safety class

 / II

 / II

 / II

Maximum pressure

8 bar

10 bar

10 bar

Reservoir content

9.5 l

20 l

50 l

Cylinder bore

47 mm

55 mm

47 mm

Stroke

37 mm

42 mm

37 mm

Fuse protection

7 A

10 A 

16 A

Ambient temperature

+5 - +40 °C

+5 - +40 °C

+5 - +40 °C

Length/width/height

400/320/630 mm

480/410/800 mm

880/350/700 mm

Weight approx.

18 kg

33 kg

46 kg

For Your Safety

Read all safety warnings and all

instructions.

 Failure to follow the

warnings  and  instructions  may  result  in  electric

shock, fire and/or serious injury. 

Save all safety warnings and instructions for fu-

ture reference.

Working safely with this machine
is  possible  only  when  the  opera-
ting  and  safety  information  are
read  completely  and  the  instruc-
tions contained therein are strictly
followed.

Before  each  use  of  the  machine,
check  the  cable  and  plug.  If  dam-
age is detected, do not use the ma-
chine.    Have  repairs  performed
only by a qualified technician. Nev-
er open the machine yourself.

Compressors should only be operated and serv-

iced by trained personnel. 

The operator of this machine is responsible for 

observing the valid instructions, and in particu-

lar for adhering to the scheduled testing times 

for the compressed air reservoir and the regula-

tions for the prevention of accidents (VGB 16).

The safety valve

 14

 has been secured against 

becoming altered. The blow-off pressure pre-set 

by the manufacturer must not be changed.

No changes may be made on the machine by 

the customer, in particular, the compressed air 

reservoir

 17

.

Caution! Danger of burning!

 When the plant is 

in operation, the unit and pressure tube

 2

 be-

come hot.

Do not place any inflammable objects in the vi-

cinity of the compressor.

Keep children and animals away from the op-

erating area and thereby prevent any injuries 

being caused by equipment connected to the 

compressor.

Do not operate the compressor without an air 

filter.

Do not move the compressor if the reservoir is 

under pressure.

Before commencing any work on the machine, 

pull out the mains plug and ensure that the plant 

is depressurised. 

Use only original Würth parts and accessories.

GB

For further notes on safety refer to enclosed Sheet

0701 221.book  Seite 12  Mittwoch, 2. Juni 2010  1:38 13

Summary of Contents for master K 210

Page 1: ...av original driftsinstruks Alkuper isen k ytt ohjeen k nn s vers ttning av bruksanvisning i original Orijinal i letim talimat terc mesi T umaczenie oryginalnej instrukcji eksploatacji Az eredeti keze...

Page 2: ...I F E P NL DK N FIN S GR TR 6 11 12 17 18 23 24 29 30 35 36 41 42 47 48 53 54 59 60 65 66 71 72 77 78 83 84 89 90 95 96 101 102 107 108 113 114 119 120 125 126 131 132 137 138 143 144 149 0701 221 bo...

Page 3: ...1 7 12 6 14 16 18 19 20 17 11 13 22 21 15 4 5 2 9 10 3 8 22 0701 221 book Seite 3 Mittwoch 2 Juni 2010 1 38 13...

Page 4: ...16 1 7 6 12 14 19 18 17 20 2 11 11 13 21 15 8 3 4 9 10 5 22 22 0701 221 book Seite 4 Mittwoch 2 Juni 2010 1 38 13...

Page 5: ...14 15 21 11 13 12 8 17 18 6 16 19 20 2 7 1 3 9 10 5 4 0701 221 book Seite 5 Mittwoch 2 Juni 2010 1 38 13...

Page 6: ...and plug If dam age is detected do not use the ma chine Have repairs performed only by a qualified technician Nev er open the machine yourself Compressors should only be operated and serv iced by tra...

Page 7: ...ny lengths be yond this require 2 5 mm2 If the cross section of the conductor is too small this will cause a volt age drop and there is no guarantee that the mo tor will start correctly Cable reels mu...

Page 8: ...ter use set the pressure reducer 21 back to 0 All Models are equipped with an additional quick coupling not reduced 12 Before connect ing more than one pneumatic tool to the com pressor please check t...

Page 9: ...r should be carried out by a W rth MasterSERVICE agent For all correspondence and spare parts orders al ways include the article number on the type plate of the machine For the current spare parts lis...

Page 10: ...itch the compressor off using the On Off switch 1 and then switch it on again On Off switch 1 is defective Contact the customer service The length of the mains connection lead is not permissible or th...

Page 11: ...can be accepted only when the machine is presented undisassembled to a W rth branch office your W rth sales representative or a customer serv ice agent for W rth pessure air and power tools Measured...

Reviews: