background image

33

decrease anticlockwise. Setting complete

Press

key

Or

other setting buttons, exit and save the setting value.

Overcurrent protection settings

Press the protection setting

key

Overvoltage protection setting is selected (curve

display interface setting will automatically jump out)

Press the

protection setting key again

The overcurrent protection

setting is selected, and the selected bit is displayed in reverse red

Shift the left and right buttons, turn the rotary encoder to increase

clockwise and decrease anticlockwise. Setting complete

Press

key

Or other setting buttons, exit and save the setting

value.

Summary of Contents for WZ-6008

Page 1: ...1 数控直流稳压电源使用说明 Instructions for use of numerical control DC stabilized voltage power supply ...

Page 2: ...2 数控直流稳压电源使用说明 产品型号 WZ5005 修订时间 2020 8 12 版本号 V1 0 注 为了更好的了解和使用本产品的全部功能 获得好的用 户体验 请仔细阅读本产品的说明书 避免误操作 ...

Page 3: ...1 2 产品技术指标 7 1 3 产品核心功能 7 1 4 操作说明 7 1 4 1 主界面 8 1 4 2 使用说明 8 1 4 2 1主界面电压电流设置 保护设 置 8 1 4 2 2快捷存储和调出 9 1 4 2 3按键锁定解锁 10 1 4 2 4曲线显示界面刻度调节 10 1 4 2 5 系统设置 11 WIFI 版电源安卓手机 APP 使用说明 13 1 手机 APP 扫码下载安装 13 2 安装注意事项 13 2 1 软件更新 14 2 2 APP 界面显示 14 ...

Page 4: ...4 2 2 1 启动完成界面 14 2 2 2 APP 主界面显示 15 2 2 3 地址选择界面显示 16 2 2 4 存储数据方式选择 17 3 APP 的使用 19 3 1 设置 WZ6008 通信接口 19 3 2 APP 智能配网 20 APP 使用注意事项 22 上位机软件的安装使用说明 24 附录 1 通讯协议 25 ...

Page 5: ...5 1 1 操作面板说明 1 1 1 前面板 1 1 2 后面板 ...

Page 6: ...6 注意事项 电源输入接口必须严格接入6 55V的稳压直流电 切勿接入交 流电或超过电压范围的电源 否则会烧毁本产品 当电流或 功率或温度过高时 风扇打开 否则关闭 当温度高于 80 度时 显示 OTP 并关闭输出 通讯端口为专用接口 请勿接别的模块或 设备 WIFI 模块和 USB 模块 RS485 模块为选配 需要请另行购 买 ...

Page 7: ...7 1 2 产品技术指标 1 3 产品核心功能 1 8 寸高清彩屏显示 安卓 APP PC 上位机 4 组快捷存储调用 多种显示界面 扩展外接 USB RS485 WIFI 一体化面板 方便装配 多重防护 1 4 操作说明 上电后 如果菜单里面设置的是 WIFI 模式 先连接 WIFI 服 务器 再显示开机界面 否则直接显示开机界面 然后进入主界 面 ...

Page 8: ...主界面 数据显示界面 统计界面 曲线界面 1 4 2 使用说明 菜单操作中 红色阴影处为当前选中菜单 绿色为未选中状 态 按方向键移动光标或切换菜单 选中后按 OK 键确认 按上或下方向键可以切换数据显示或统计界面 1 4 2 1 主界面电压电流设置 保护设置 电压设置 按下电压设置键 电压设置被选中 曲线显 示界面设置会自动跳出 设置选中位反红显示 左右按键移位 转动旋转编码器顺时针加 逆时针减 设定完成 按 键 ...

Page 9: ...按键移位 转动旋转编码器顺时针加 逆时针减 设定完成 按 键 或其它设置按键 退出并保存设置值 过压保护设置 按下保护设置键 过压保护设置被选中 曲线显示界面设置会自动跳出 设置选中位反红显示 左右按 键移位 转动旋转编码器顺时针加 逆时针减 设定完成 按 键 或其它设置按键 退出并保存设置值 过流保护设置 按下保护设置键 过压保护设置被选中 曲线显示界面设置会自动跳出 再按下保护设置键 过 流保护设置被选中 设置选中位反红显示 左右按键移位 转动 旋转编码器顺时针加 逆时针减 设定完成 按 键 或 其它设置按键 退出并保存设置值 ...

Page 10: ... 调出 M1 M2 M3 M4 设置当前 输出电压 输出电流 过压保护 过流保护值 设置完自动存储 1 4 2 3 按键锁定解锁 长按 键 2S 以上 可以手动锁定或者解锁键盘 在通信状态下 通信状态标志变为绿色 此时按键也自动被 锁定 通信断开 标志位变成白色 自动解锁 1 4 2 4 曲线显示界面刻度调节 在曲线显示界面 坐标轴刻度值大小根据每格刻度决定 在 下方默认选中电压刻度设置 按左右方向键更改选中设置对象 设置值反红显示 转动旋转编码器改变每刻度大小 ...

Page 11: ...调整主显界面 可以选择数字经典界面或曲线显示界面 2 设备地址可以从 1 255 之间设置 3 通信接口可以设置为 COM 或 WiFi 接口 COM 口为后部接 RS485 USB 模块的接口 选中后显示 WIFI 口为接 WIFI 模 块的接口 选中后通信图标为 通信状态下都变为绿色 4 COM 接 口 通 信 速 率 可 以 设 置 为 9600 19200 38400 57600 115200 WiFi 下通信速率固定为 115200 5 系统语言可以设置为简体中文 英文 6 打开开机输出时 开机后自动打开输出 关闭时 开机后 电源输出处于关闭状态 ...

Page 12: ...自动关闭 8 打开按键声音后 按动按键蜂鸣器提示 关闭后按动按键 为静音状态 9 打开开机图片后 开机先显示开机 logo 图片然后进入主 界面 关闭后直接进入主界面 10 可以设置为 0 6 共七级亮度 11 系统校零确定后会打开对话框 当系统长期使用有小电流 时执行此操作 左右按键选择确认或取消 按确定键退出 12 恢复出厂确定后会打开对话框 当使用过程中出现异 常时可执行此操作 恢复出厂设置 左右按键选择确认或取消 按确定键退出 13 系统版本显示当前系统系统版本号 ...

Page 13: ...13 ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 点击菜单图标 打开侧滑界面 点击地址选择 操作 如图 侧滑界面中的语言选项和关于选项操作和地址选 择类似 点击进入界面进行操作 ...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...19 这里需要注意 要先把 APP 打开 再开启 WZ5005 设置 WZ5005 的通信接口模式 APP 只在 WIFI 模式下 进行使用 具体操作如上图 ...

Page 20: ...20 ...

Page 21: ...21 接上页 APP 配网操作步骤中的第 5 步 第 6 步操作 演示 ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ...4 或以上版本 电脑没有的话 请自行安装 本软件由本公司开发 不带有病毒 如果杀毒软件提示请允 许它的所有功能 否则会影响软件的正常运行 打开资料包软件 双击图标 打开软件 通过 USB 数据线或 USB 转 RS485 连接带有 USB 或 RS485 模 块的设备 选择好通讯端口号 点击打开 成功后指示灯变成红 色 然后选择好设备地址 点击连接设备 成功后指示状态变为 绿色 软件和设备建立连接进行实时通讯 通过软件可以简单的设置输出电压 输出电流 保护电压 过流保护以及输出开关 显示当前输出电压 输出电流 输出功 率 工作状态等 ...

Page 25: ... 设置操作模式 0 为面板操作模式 1 为远程操作模式 0x21 1 设置新通讯地址 1 255 0x22 1 设置 电源输出状态 0 为输出OFF 1 为输出ON 0x71 1 设置时间容量能量统计运行状态 0 暂停 1运行 0x72 1 清空时间容量能量统计 0x23 1 读取 当前电源输出状态 0 为输出OFF 1 为输出ON 2 读取 当前工作状态 0 CV模式 1 CC模式 3 读取 当前系统状态 0 正常 1 过压 2 过流 3 过温度 4 输入欠压 0x24 读取产品 信息 1 读取产品型号 2 读取产品版本高字节 3 读取产品版本低字节 4 读取出厂编号的高字节 5 读取出厂编号的次高字节 6 读取出厂编号的次低字节 7 读取出厂编号的低字节 0x25 0x26 读取和设 置系统参 数 1 设备地址 2 开机界面 0无 1无治 3 开机默认输出 0无 1有 4 声音标志位 ...

Page 26: ...高字节 8 读取当前功率值的次高字节 9 读取当前功率值的次低字节 10 读取当前功率值的低字节 0x2A 读取当前 信息 1 读取当前时间值的高字节 2 读取当前时间值的次高字节 3 读取当前时间值的次低字节 4 读取当前时间值的低字节 5 读取当前能量值的高字节 6 读取当前能量值的次高字节 7 读取当前能量值的次低字节 8 读取当前能量值的低字节 9 读取当前容量值的高字节 10 读取当前容量值的次高字节 11 读取当前容量值的次低字节 12 读取当前容量值的低字节 13 读取当前温度值的高字节 14 读取当前温度值的低字节 0x2B 0x2C 读取和设 置信息 1 当前保护电压值的高字节 2 当前保护电压值的低字节 3 当前保护电流值的高字节 4 当前保护电流值的低字节 5 当前设置电压值的高字节 6 当前设置电压值的低字节 7 当前设置电流值的高字节 8 当前设置电流值的低字节 ...

Page 27: ...ower supply Product model WZ5005 Revision time 2020 8 12 Version No V1 0 Version No note in order to better understand and use all functions of the product and obtain a good user experience please read the product manual carefully to avoid misoperation ...

Page 28: ...28 1 1Operation panel description 1 1 1 Front Panel 1 1 2 Rear panel ...

Page 29: ...e product will be burnt When the current or power or temperature is too high the fan is turned on otherwise the fan is turned off When the temperature is higher than 80 degrees the OTP is displayed and the output is turned off The communication port is a special interface do not connect other modules or devices WIFI module USB module and RS485 module areoptional please purchase separately ...

Page 30: ...iple display interfaces Extended external USB RS485 WIFI Integrated panel for easy assembly Multiple protection 1 4Operating instructions After power on if WiFi mode is set in the menu connect WiFi server first and then display the power on interface otherwise directly display the power on interface and then enter the main interface 1 4 1main interface ...

Page 31: ...nstructions In the menu operation the red shadow is the currently selected menu and the blue is not selected Press the direction key to move the cursor or switch the menu and then press OK to confirm Press up or down direction key to switch data display or statistics interface ...

Page 32: ...setting Press the current setting key Current setting is selected curve display interface setting will automatically pop up Set the selected bit to display in reverse red Shift left and right buttons Rotate the rotary encoder to add clockwise and decrease anticlockwise Setting complete Press key Or other setting buttons exit and save the setting value Overvoltage protection settings Press the prot...

Page 33: ...tting is selected curve display interface setting will automatically jump out Press the protection setting key again The overcurrent protection setting is selected and the selected bit is displayed in reverse red Shift the left and right buttons turn the rotary encoder to increase clockwise and decrease anticlockwise Setting complete Press key Or other setting buttons exit and save the setting val...

Page 34: ... the communication status flag turns green at this time the key is automatically locked the communication is disconnected the flag bit turns white and the key is automatically unlocked 1 4 2 4Scale adjustment of curve display interface In the curve display interface the scale value of coordinate axis is determined by each scale Select the voltage scale setting by default below press the left and r...

Page 35: ...hoose digital classic interface or curve display interface 2 The device address can be set from 1 255 3 The communication interface can be set as COM or WiFi interface COM port is the interface connecting RS485 and USB module at the rear Show when selected The WiFi port is the interface connecting to the WiFi module When selected the communication icon is It turns green in communication state 4 Th...

Page 36: ...f the output will be turned off automatically 8 When the button sound is turned on press the button buzzer to prompt and when it is turned off press the button to mute 9 After opening the boot image the boot logo image will be displayed before entering the main interface and then directly entering the main interface after closing 10 It can be set to 0 6 with seven levels of brightness 11 The dialo...

Page 37: ...on is restored This operation can be performed when there is an exception in the use process to restore the factory settings Press the left and right keys to confirm or cancel and press the OK key to exit 13 System version displays the current system version number ...

Page 38: ...38 ...

Page 39: ...39 ...

Page 40: ...40 Click the menu icon to open the sideslip interface click the address selection and the operation is as shown in the figure ...

Page 41: ...41 The language option in the sideslip interface is similar to the option operation and address selection Click to enter the interface for operation ...

Page 42: ...42 ...

Page 43: ...43 ...

Page 44: ...oted here that the app should be opened first and then the wz6008 should be opened to set the communication interface mode of wz6008 The app is only used in WiFi mode The specific operation is shown in the figure above ...

Page 45: ...45 Please refer to the following picture for specific operation steps and pay attention to the operation sequence in the next step 2 Wait until the IP address appears on the wz6008 interface ...

Page 46: ...46 ...

Page 47: ...47 ...

Page 48: ...48 ...

Page 49: ...49 ...

Page 50: ...not have one please install it yourself This software is developed by our company without virus If the antivirus software prompts please allow all its functions otherwise it will affect the normal operation of the software Open package software Double click Icon Open the software Connect the device with USB or RS485 module through USB data line or USB to RS485 Select the communication port number ...

Page 51: ...tate turns green after work Establish connection between software and equipment for real time communication Through the software the output voltage output current protection voltage over current protection and output switch can be simply set Display the current output voltage output current output power working status etc ...

Page 52: ...command 90H is returned Command word register content 0x20 1 Set operation mode 0 is panel operation mode 1 is remote operation mode 0x21 1 Set new address 1 255 0x22 1 Set power output status 0 is output OFF 1 is output ON 0x71 1 Set time capacity energy statistics operation state 0 suspend 1 operation 0x72 1 Clearing time capacity energy statistics 0x23 1 Read the current power output status 0 i...

Page 53: ...rrent information 1 Read the high byte of the current time value 2 Read the next highest byte of the current time value 3 Read the next lower byte of the current time value 4 Read the low byte of the current time value 5 Read the high byte of the current energy value 6 Read the next highest byte of the current energy value 7 Read the second lowest byte of the current energy value 8 Read the low by...

Page 54: ...54 12 13 14 ...

Reviews: