7
Setup and Configuration
The DPS850 can be set up and configured locally using the four button user
interface or remotely with the InfoGate system.
USER INTERFACE
Indicator LED’s
Three LED indicators are located to the left of the accessory output XLR
connector to provide instant information as to the state of the DPS850.
Red
Power indicator. On anytime power is present.
Green
DMX signal indicator. Flashes when the DPS850 is receiving a
DMX signal. Indicator is active for one minute after power up or the
last button press. The LED can be reactivated by pressing any
button.
Yellow
RDM signal indicator. Flashes when the DPS850 is receiving RDM
messages. Indicator is active for one minute after power up or the
last button press. The LED can be reactivated by pressing any
button.
Seven segment display
User menus are displayed on a three character seven segment display. The
display is active for one minute after power up or the last button press. The
display can be reactivated by pressing any button.
Pushbutton interface
Four buttons are used to navigate the menu and select configuration options.
Menu
Used to select between menu items.
+
Increment configuration.
-
Decrement configuration.
Enter
Used to enter a menu item or confirm a configuration change.