22
Sprayer Operation
Preparing The Sprayer For Storage
(1)
Flush the tank, pump and lines with clean water.
(2)
Remove cap from the main tank fill valve and open
ball valve to drain the spray tank.
(3)
Remove cap from fresh water tank valve and open
ball valve to drain the fresh water tank.
(4)
Remove the strainer base and screen to drain the
suction plumbing. Remove pump plug to drain pump
housing.
Figure C30
Remove Strainer Base To Drain Tank
Figure C31
Light Plug and Boom Lock Chain
(5)
Remove tips and strainers from the nozzle bodies.
Clean strainers and check tips for wear and damage.
(6)
Open controller ball valves. Allow the system to
drain completely to prevent any parts from breaking due to
freezing. Loosen at least one cap from each boom section
to allow any water inside the nozzle bodies to drain. Check
any fittings where water can collect and disconnect to allow
drainage. Reconnect all fittings and ensure tightness once
system is drained.
(7)
For further protection, pump environmentally safe
antifreeze or winter grade windshield washing fluid into
the lines.
Sprayer Transport
Before transporting the sprayer on any public roads, make
sure that the sprayer lights are plugged into the tractor, the
boom is lowered into the boom rest, and the boom lock
chains are pinned.
Light Plug >
Summary of Contents for Spray Wyng II