CONNECTION

1

2

!

!

!

3

4

5

6

7

8.     Connection

        

Do not connect the Enado Controller to 

the mains until you have made all the following 

connections.

        Connect a good quality, well-terminated Cat5e/6 

cable with RJ45 connectors wired to the 568B standard 

at both ends to the Enado Ethernet switch and the router 

or primary network switch. Ensure the cable is tested 

and measures less than 100m/328ft, with all connectors 

pushed securely to ports and supported by connector 

strain relief clips to prevent them from becoming loose.

        The quality of cable and RJ45 termination is 

essential for successful distribution transmissions. 

Poor cable and terminations lead to intermittent 

performance and longer install times.

        The IR TX receiver window on the front panel & the

IR TX port on the rear of the Enado Controller are 

electronically linked and should not be used together.

Rear IR IN should only be connected if it is not possible to 

receive IR signals via the front panel for learning, such as 

if the IR TX window is obstructed or the unit is enclosed 

so cannot receive an IR signal from a handset.

In such cases the rear IR TX receiver eye should be 

placed in clear line of site to the control device used to 

control.

        The rear of the Enado controller has 16 x IR outputs 

used to control displays or other devices in zones and 

sources local to the controller, with the user able to 

designate the balance of output devices or local sources 

to be controlled through the system.

For example, if the application requires an even balance 

of inputs and outputs for control within an 8x8 matrix 

distribution, the user should connect 8 IR outputs from 

the Enado Controller to the IR RX ports of the matrix 

using the supplied mono IR Link cables to enable control 

of output devices in display zones.

        The remaining 8 Enado IR outputs should be 

connected to sources local to the controller via the 

supplied Y IR emitters, with one jack connecting to the IR 

ports of the Enado Controller and the other connecting 

to the corresponding source IR TX ports on the matrix to 

enable IR pass-through.

        IR eyes should be attached with the adhesive 

backing directly over the infrared receiving area 

of sources, ensuring there is a clear line-of-sight 

with the remote control handset used to control. 

Location of the IR eye may need to be adjusted later 

to achieve best IR performance.

NOTE: Infrared windows can be seen by shining a 

flashlight onto the front of the device – the IR sensor 

will likely appear as a small round diode behind the 

fascia.

        For integration of a control system, connect an 

RS232 cable between a matrix and the Enado Controller 

– serial control for up to 4 matrices is supported, with 

each matrix requiring individual RS232 connection to 

ports 1-4 of the Enado Controller.

        Connection of trigger GPIO (General Purpose input/

output) and sensor input system. See 6ii on Rear Panel 

description.

        Connect the power supply, making sure to ground 

the chassis first to prevent electrical build up before 

turning on the power supply.

Required Cable Types:

• 

IR (to source): WyreStorm Enado ‘Y’ IR Emitter

• 

IR (Enado to matrix): WyreStorm IR Link cable (CAB-IR-

LINK - 5v to 12v)

• 

RS232: Null modem

• 

Ethernet: Straight ‘patch’ lead

Front IR RX

Rear IR RX

Summary of Contents for Enado

Page 1: ...ction Manual WyreStorm EnadoTM User Interface Controller eNA 001 010 WyreStorm Enado Controller with 16x IR 4x RS232 8x Ethernet and 4x I O Sensors Thank you for choosing this WyreStorm product Please...

Page 2: ...an run on any client device that offers a compatible web interface making the controller ideal for both professional and residential control For further information on this product and other WyreStorm...

Page 3: ...32 control and Ethernet pass through please see our full HDBaseT or HDBT Lite range of matrices transmitters receivers and extender sets USB to 5V Cable Part Number CAB USB 5V Full remote access enabl...

Page 4: ...8 IR blaster IR TX LED power indicator lit when powered LED work indicator lit when working set by software LED warn indicator lit when warning set by software IR IN IR RX receiver input IR blaster I...

Page 5: ...the Y shape dual jack IR emitters supplied with the controller avoids having two IR emitters on the source device IR Link cables are used to connect the matrix TX to Enado The RS232 lead should be a c...

Page 6: ...example if the application requires an even balance of inputs and outputs for control within an 8x8 matrix distribution the user should connect 8 IR outputs from the Enado Controller to the IR RX port...

Page 7: ...R MATRIX AND EXPAND DISTRIBUTION Full control of connected sources and displays through the Enado central controller from any global location via the multi platform browser based Enado User Interface...

Page 8: ...is automatically generated from the data used in the Standard UI configuration with some Compact UI specific configuration options This allows quick and easy editing and creation of the different scre...

Page 9: ...display calculated from the display device 9 Room Zone Global controls present in every activity page per room zone 10 System Settings main access to system configuration and management NOTE See Enado...

Page 10: ...e updating process has completed and the live configuration UI s are accessible from a web browser ii Accessing the configuration UI guide To access the full Configuration UI guide Select Editor User...

Page 11: ...an IP address conflict if there are other devices with statically assigned addresses on the network Central devices should where possible have static addresses assigned or have static addresses assign...

Page 12: ...the manufacturer or parts possessing the same characteristics as the original parts Be aware unauthorised substitutes may result in fire electric shock or other hazards and will invalidate your warran...

Page 13: ...warrantor is not liable for incidental or consequential damage resulting from the use of this product or arising out of any breach of this warranty For example damages for lost time the cost of havin...

Page 14: ...X Input Ethernet RS232 Sensor I O 1 1 2 3 2 4 5 3 6 7 4 8 9 5 10 11 6 12 13 7 14 15 8 16 Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cable Cab...

Page 15: ...15 US CAN MEX 1 518 289 1294 Toll Free Technical Support 1 844 280 WYRE 9973 NOTES 15 21 Notes...

Page 16: ...A Office Unit 22 Ergo Business Park Swindon Wiltshire SN3 3JW UK Tel 44 0 1793 230 343 WyreStorm Technical Support US 1 844 280 WYRE 9973 UK 44 0 1793 230 343 Email support wyrestorm com WyreStorm Tec...

Reviews: