Page 7
To Enter any Mode:
1)
Press and hold down the PROGRAM button and release it when the LED starts
blinking green.
You are now in Mode 1 (Setting New Primary Address).
2)
Tap the PROGRAM button once. The LED is blinking red.
You are in Mode 2
(Setting New Scene Addresses).
3)
Tap the PROGRAM button once. The LED is blinking orange.
You are in Mode 3
(Setting Channel Enables).
4)
Tap the PROGRAM button once. The LED is alternating green and red
. You are
in Mode 4 (Setting Ramp Rates).
5)
Tap the PROGRAM button once. The LED is alternating green and orange.
You
are in Mode 5 (Setting Advanced Programming Options).
LED Color Indicator
Program Mode
Mode Name
LED Pattern
Normal Operation
Solid Red
Mode 1
Setting New Primary Address
Blinking Green
Mode 2
Setting New Scene Addresses
Blinking Red
Mode 3
Setting Channel Enables
Blinking Orange
Mode 4
Setting Ramp Rates
Alternating Green and Red
Mode 5
Advanced Programming Options
Alternating Green and Orange
Mode 1 Programming - Setting the Primary Address
1)
Enter Mode 1.
See To Enter any Mode section.
2)
Transmit X-10 address.
This address will be the new Primary Address.
3)
Press All-Lights-On key.
The product stores new Primary Address into memory.
4)
Press All-Lights-On key 3 times.
The product is transferred out of programming
mode and into normal operation.