background image

Page 7

To Enter any Mode:

1) 

Press and hold down the PROGRAM button and release it when the LED starts
blinking green.

 You are now in Mode 1 (Setting New Primary Address).

2) 

Tap the PROGRAM button once. The LED is blinking red. 

You are in Mode 2

(Setting New Scene Addresses).

3) 

Tap the PROGRAM button once. The LED is blinking orange.

 You are in Mode 3

(Setting Channel Enables).

4) 

Tap the PROGRAM button once. The LED is alternating green and red

. You are

in Mode 4 (Setting Ramp Rates).

5) 

Tap the PROGRAM button once. The LED is alternating green and orange. 

You

are in Mode 5 (Setting Advanced Programming Options).

LED Color Indicator

Program Mode

Mode Name

LED Pattern

Normal Operation

Solid Red

Mode 1

Setting New Primary Address

Blinking Green

Mode 2

Setting New Scene Addresses

Blinking Red

Mode 3

Setting Channel Enables

Blinking Orange

Mode 4

Setting Ramp Rates

Alternating Green and Red

Mode 5

Advanced Programming Options

Alternating Green and Orange

Mode 1 Programming - Setting the Primary Address

1) 

Enter Mode 1.

 See To Enter any Mode section.

2) 

Transmit X-10 address.

 This address will be the new Primary Address.

3) 

Press All-Lights-On key.

 The product stores new Primary Address into memory.

4) 

Press All-Lights-On key 3 times.

 The product is transferred out of programming

mode and into normal operation.

Summary of Contents for X10 PRO XP4LS

Page 1: ...Power Lighting Module INSTALLATION AND OPERATING INSTRUCTIONS For Models XP4LS XP1LS 10012 North Dale Mabry Ste 115 Tampa FL 33618 Tel 800 TECH 003 Fax 813 265 1011 Email x10protec x10pro com Web www...

Page 2: ...ur une fixture fluorescente or un transformateur INSTALLATION Installation Notes a Be sure that power to the supply circuit has been disconnected by removing fuse or turning circuit breaker off Instal...

Page 3: ...ght circuit via the Lighting Module control inputs Wiring Notes a Remote switches require a Line Voltage input Black that is always hot Do not connect to the load switched circuit b The gray wire on t...

Page 4: ...t for simple and inexpensive installation The home run wiring scheme is very different than conventional wiring methods The conventional way typically taps off or daisy chains as many fixture switch s...

Page 5: ...control devices including those manufactured by PCS Lutron Lightolier Leviton X 10 and ACT d provides ample wiring room for large number of wire nut connections often required e circuits can be easil...

Page 6: ...is is the normal operating state of the Lighting Module Mode 1 mode used to set primary address of the channel s Mode 2 mode used to set scene addresses to the scene numbers Mode 3 mode used enable or...

Page 7: ...are in Mode 5 Setting Advanced Programming Options LED Color Indicator Program Mode Mode Name LED Pattern Normal Operation Solid Red Mode 1 Setting New Primary Address Blinking Green Mode 2 Setting Ne...

Page 8: ...nnel numbers 1 through 4 MM2s have channel numbers 1 and 2 SS1s have only channel number 1 5 Press the ON key or OFF key Pressing ON or OFF key will determine if the channel will respond or not respon...

Page 9: ...mber 1 5 Press the ON key or OFF key Pressing ON or OFF key will determine if the channel will respond or not respond to the Scene Address 6 Press All Lights On key The product stores new setting into...

Page 10: ...rogramming mode and into normal operation Numbered Key on Transmitter Controller Advanced Programming Option Default Setting 1 Soft Start Enabled 2 All Lights On Enabled 3 All Lights Off Enabled 4 All...

Page 11: ...IME ADDR LIGHTING LEVELS Ch 1 Channel 1 A1 100 70 40 20 100 70 40 20 100 70 40 20 100 70 40 100 Ch 2 Channel 2 A2 100 70 40 20 100 70 40 20 100 70 40 20 100 70 40 100 Ch 3 Channel 3 A3 100 70 40 20 10...

Page 12: ...ypes Incandescent Magnetic Low Voltage Incandescent Magnetic Low Voltage Input Power 125 VAC 125 VAC Min Load 60 W 60 W Min Receive Level 5 mV 5 mV Max Noise Rejection 350 mV 350 mV Connections 16 AWG...

Reviews: