630140_1
XFIRE_1200_GB_Manual_R
‐
emotion
14.0 Converting to G31 Propane Gas:
Where a conversion to propane gas is needed, the following steps should be followed
14.1
First you need to remove the burner by
removing the screw holding it in place on the
left hand side of the firebox (Fig. 1).
Then remove the 1.9mm burner jet (Fig. 2)
and replace it with the 1.3mm jet supplied in
the kit.
Now remove the gas pipe fitting under the
pilot (Fig. 3) and remove the No.48 pilot Jet
(Fig. 4) and replace it with the No.46 pilot jet
supplied in the kit.
Replace pilot line.
Adjust the Primary Aeration Collar on the
burner to the Propane position as shown in
the diagram below, then place the burner into
position and screw it in place.
The gas regulator needs to be converted from
the Natural Gas setting to the Propane setting.
The regulator is located on the left hand side of
the control tray, at the base of the fire. To change
the regulator between Natural Gas and Propane,
unscrew the top cap off the regulator and pull the
plunger from it. Re-insert the plunger on the
opposite side (as shown in the diagram to the
right) and screw the assembly back in the stack