Radio Remote Control FFB2000-Pro
X-Floc Dämmtechnik-Maschinen GmbH
Page 5 of 9
Rosine-Starz-Straße 12 · 71272 Renningen · Germany
Phone +49-7159-80470-30 · Fax -40 | info@x-floc.com · www.x-floc.com
Parameters
The control offers several settings which can be adjusted through the parameters. To adjust the paramters
one must change into the parameter mode, see Basic settings.
Parameter assignment
No.
Description
Value range
Factory settings
1
Radio channel
1-4
1
2
Material start delay
1 (=0 sec.)…
10 (=9 sec.)
3: Start delay 2 sec.(Ex.: EM3xx, M95, M99-DS-
Pro)
5: Start delay 4 sec. (Ex.: EM5xx, EM4xx, M03)
3 (2 seconds)
3
Air switch off delay
1 (=0 seconds.)…
10 (=9 seconds.)
1 (0 seconds)
4
Automatic shutdown time
delay
1 (=0 seconds)…
10 (=9 seconds)
3 (2 seconds)
5
Overpressure signalled with a
"beep" noise
1 (inactive) …
2 (active)
2
6
Reaction time of dynamic
pressure regulation
1 (50ms)-
10 (500ms)
3 (150ms)
7
Machine model / control
signal air
2,4
2: Control signal air 0-10V (Ex.: EM5xx,
EM4xx, EM3xx, M03, M95K, M99-DS-Pro)
4: Control signal air 0-15V (Ex.: M95A-M95H)
-
8-9
Reserved
-
-
10
Test mode
1-10
1