Basic Settings

 

 

Button combination 

Function 

Explanation 

The receiver and the transmitter must 

both be switched on. Press the blue 
"learn" button on the receiver.

 

Tune transmitter to 

receiver. 

After the "learn" button is pressed, the receiv-

er goes in to learn mode for 30 seconds. The 
LED above the "learn" button flashes four 
times and the controls make a beep noise to 
confirm successful tuning. Controls automati-

cally switch out of learn mode. 

>

 

10

 

Sec

.

 

 

Firmware version 1.0:

 

Switch to parameter 
mode. 

The air and material LED flashes on and off. 
The parameter is displayed on the air volume 

scale. The parameter value is displayed on the 
material volume scale. 

 + 

 and 

 

Firmware version 1.4:

 

Switch to parameter 
mode. 

The air and material LED flashes on and off. 

The parameter is displayed on the air volume 
scale. The parameter value is displayed on the 
material volume scale. 

 

Parameter selection. 

The parameter value is displayed on the 1-10 
air volume scale. For parameter descriptions, 

see Parameter assignment. 

 

Parameter setting. 

The parameter value is displayed on the 1-10 
material volume scale. For value ranges and 

descriptions, see Parameter assignment. 

>

 

5

 

Sec. 

 

Reset all parameters to 
factory settings. 

Please note, all parameter settings are reset to 
factory settings, see Parameter assignment. 

>

 

5

 

Sec

.

 

 

Switch back to operat-

ing mode. 

 

 
 

Further Information 

 

Button combination 

Function 

Explanation 

 

Plug in the charging device and connect 
to the hand held controls 

 

Charging the hand 
held controls.

 

Switch off the hand held controls - power off. 
(Charging only possible when device is 

switched off). Active charging is indicated 
with the yellow LED (air start) and a running 
light on the LED material volume scale. Charg-
ing time, approx. 180 minutes.

 

Green LED on.

 

Hand held controls 

fully charged. 

Green overpressure display LED lights up. No 

other LEDs light up. Charging device can be 
disconnected. 

Connect the connection cable to the 

auxiliary connection on the hand held 
controls and the receiver. 

Operation in cable 

mode (if you have a 
connection cable). 

If radio contact is not possible, or if the batter-

ies are flat you can continue to work with a 
cable connection. Active cable connection is 
confirmed with a short beep. 

Summary of Contents for FFB2000-Pro

Page 1: ...Radio Remote Control FFB2000 Pro Original Operating Instructions Version 1 0 1 4 X Floc D mmtechnik Maschinen GmbH Rosine Starz Stra e 12 71272 Renningen Germany Phone 49 7159 80470 30 Fax 40 info x f...

Page 2: ...ine s control socket Firmware version 1 0 and 1 4 Different operating modes of the radio remote control with firmware version 1 0 and 1 4 be identified as follows Button combination firmware version 1...

Page 3: ...ial flow if not already activated will not switch on after the delay time factory setting 2 seconds 1 Material and air flow off Material flow switches off straight away air flow switches off factory s...

Page 4: ...bination firmware version 1 4 Button combination Function Explanation 2 Automatic shut down activation The green overpressure display flashes The delay time before shut down can be set with parameter...

Page 5: ...ory settings 1 Radio channel 1 4 1 2 Material start delay 1 0 sec 10 9 sec 3 Start delay 2 sec Ex EM3xx M95 M99 DS Pro 5 Start delay 4 sec Ex EM5xx EM4xx M03 3 2 seconds 3 Air switch off delay 1 0 sec...

Page 6: ...is displayed on the 1 10 air volume scale For parameter descriptions see Parameter assignment Parameter setting The parameter value is displayed on the 1 10 material volume scale For value ranges and...

Page 7: ...mal The charging cir cuit is equipped with temperature monitoring and reacts accordingly Please note The charger should not be connected to the hand held controls without batteries and equally the bat...

Page 8: ...life approx 3 years Operating time Approx 30 depending on operating intensity Transmitter power input 0 15mA with 3 6V Supply voltage optional 6V DC with RS 485 Charging voltage input 12V DC 9 16V DC...

Page 9: ...nterfere the radio connection Right Choose channel in such way that interferences are avoided or use a connector cable between sender and receiver Wrong Metal concrete walls and similar obstruct the r...

Reviews: