background image

 

Radio Remote Control FFB2000-Pro 

 

Page 8 of 9 

 

  

X-Floc Dämmtechnik-Maschinen GmbH

 

 

Rosine-Starz-Straße 12 · 71272 Renningen · Germany 

 

Phone +49-7159-80470-30 · Fax -40 | info@x-floc.com · www.x-floc.com 

 

Technical Data 

 

Receiver power supply. 

20-28V DC 

Receiver power input 

12mA bei 24V 

Hand-held transmitter power 

supply. 

3.6V DC 

Rechargeable battery type 

NiMH-rechargeable battery, Type AAA, quick charge capable (1C), Capacity 700 – 

1000 mAh.  
Examples: Sanyo Eneloop HR-4UTGB, Panasonic HHR-80AAAB, Duracell Stay-
charged AAA 

Rechargeable battery life 

approx. 3 years 

Operating time 

Approx. 30 depending on operating intensity. 

Transmitter power input 

<0.15mA with 3.6V 

Supply voltage optional 

6V DC with RS 485 

Charging voltage input 

12V DC (9-16V DC) / 0.5A 

Operating temperature range 

-20°C - +65°C 

Radio frequency: 

4 channels, manually adjustable 433.62MHz, 433.82 MHz, 434.02MHz und 
434.22MHz 

Radio peformance 

<= + 10 dBm to 50 Ohm 

Aerial connection 

50 Ohm 

Communication 

Bidirektional, GFSK modulation 

Enable communication 

Tune the hand held controls 

Baud rate 

19200 b/s 

Interface 

RS 485 (has priority over radio communication) 

Outputs 

3 digital outputs und 2 analogue outputs, 0-15V 

Moisture content 

15% to 95% rel., no condensation 

Protection class 

IP 40 

Range 

With no interference, >100 m 

Summary of Contents for FFB2000-Pro

Page 1: ...Radio Remote Control FFB2000 Pro Original Operating Instructions Version 1 0 1 4 X Floc D mmtechnik Maschinen GmbH Rosine Starz Stra e 12 71272 Renningen Germany Phone 49 7159 80470 30 Fax 40 info x f...

Page 2: ...ine s control socket Firmware version 1 0 and 1 4 Different operating modes of the radio remote control with firmware version 1 0 and 1 4 be identified as follows Button combination firmware version 1...

Page 3: ...ial flow if not already activated will not switch on after the delay time factory setting 2 seconds 1 Material and air flow off Material flow switches off straight away air flow switches off factory s...

Page 4: ...bination firmware version 1 4 Button combination Function Explanation 2 Automatic shut down activation The green overpressure display flashes The delay time before shut down can be set with parameter...

Page 5: ...ory settings 1 Radio channel 1 4 1 2 Material start delay 1 0 sec 10 9 sec 3 Start delay 2 sec Ex EM3xx M95 M99 DS Pro 5 Start delay 4 sec Ex EM5xx EM4xx M03 3 2 seconds 3 Air switch off delay 1 0 sec...

Page 6: ...is displayed on the 1 10 air volume scale For parameter descriptions see Parameter assignment Parameter setting The parameter value is displayed on the 1 10 material volume scale For value ranges and...

Page 7: ...mal The charging cir cuit is equipped with temperature monitoring and reacts accordingly Please note The charger should not be connected to the hand held controls without batteries and equally the bat...

Page 8: ...life approx 3 years Operating time Approx 30 depending on operating intensity Transmitter power input 0 15mA with 3 6V Supply voltage optional 6V DC with RS 485 Charging voltage input 12V DC 9 16V DC...

Page 9: ...nterfere the radio connection Right Choose channel in such way that interferences are avoided or use a connector cable between sender and receiver Wrong Metal concrete walls and similar obstruct the r...

Reviews: