M99 minifant operating instructions
Version M99E 20.02.2014
Page 25 of 35
7 Technical data / radio remote control operating instructions
7.1 Hand-held
transmitter
Important:
The hand-held receiver has activation protection (keypad-lock).
To activate the transmitter, a button must be pressed (air or material) twice in quick succession
(double click).
Hold down the OFF button for 5 seconds:
Keypad-lock activated
Double click the "air" button:
Keypad-lock deactivated
7.1.1 Operation
1. The
hand-held
receiver has activation protection (can be switched off; disa-
bled when delivered from factory). To activate the transmitter, a button must
be pressed twice in quick succession (double click).
2. Once successfully activated, the transmitter starts to
establishaconnection
.
The
red LED
lights up.
3. As soon as there is a connection with the receiver, the red LED lights up. If a
button is pressed
, the
green LED
lights up.
4. As long as the blower or the material flow is activated, the green LED flashes
at second intervals.
5. If the OFF button is pressed, the blower and the material flow will stop.
If the keys are pressed incorrectly, the red LED will flash repeatedly.
Tips:
The distance required to switch on the machine is shorter than the distance required to switch it off.
If the transmitter loses connection with the receiver, after five seconds it will switch off.
To re-establish a connection, move closer to the receiver.
If the distance between the transmitter and receiver is too big, the red LED on the transmitter lights
up and after a few seconds, the receiver completely shuts down. In this case, do not mount the
transmitter directly onto the machine or reduce the distance to the receiver.
7.1.2 Buttons
Symbol Description
Blower is switched on.
Material flow is switched off.
The blower will be switched on, if not already on.
The switching on of material flow can be delayed (
-> Dip-switch
)
OFF
Blower and material flow are switched off.
Optional switch (function-change) e.g. vacuum cleaner
OFF