1.  While unit is unplugged and cool, unscrew nozzle a very front of unit(fig.1) and 

clean out unobstructed. 

2.  Empty all fog fluid from the machine and  replace with cleaning solution in the 

tank. Plug unit in and to warm as usual. 

3.  Run unit in a well ventilated area unit tank is empty. 
4.  Replace nozzle. 
5.  Cleaning us now complete. Unplug and refill with a quality water based fog fluid 

once cool. 

All fog machine are prone to clogging due to the consistency of fog fluid and the 
high temperatures at which it vaporizes.  However a well maintained machine should 
provide years of reliable use.  
The body of the unit may be cleaned with a dry cloth. Store dry. 

 

 Maintenance & servicing  

Do not allow fog fluid to become contam inated. Always replace cap after use.  
Work on internal parts should be carried out by a qualified technician. Removal of 
any covers is considered a breach of warranty and will not be covered under any 
such agreement unless authorized first by company. 

Troubleshooting  

If you experience low output, pump noise or no output at all, unplug immediately. 
Check fluid level, the external fuse, remote connection and main power supply, if all 
appear to be ok, plug the unit in again.  If fog does not come out after holding the 
remote control button for 30 seconds, check the hose attached to the tank to make 
sure there is fluid going through the hose. If you are unable to determine the cause 
of the problem.  Do not simply continue to   push the remote control button as this 
may damage the unit. contact us for servicing. 

7.  Beware of consideration around the nozzle. Consider carefully when mounting. 

Caution : 

1.  Do not obstruct the nozzle. Fog output is

of the  nozzle during operation. Never aim the nozzle directly at people or naked 
flames. 

2.  Danger of burns. Keep out of reach of children. Do not leave machine 

 

unattended. 

3.  Output nozzle becomes very hot during operation(300 degree).keep flammable 

materials at least 50cm(20

away from the nozzle. 

).

4.  Always allow the fogger to cool down before cleaning or servicing. 

5.  Never use any other type of liquid other than water based quality fog fluid. 

6.  Never drink fog liquid. If its ingested, call a doctor immediately. If fog fluid 

comes into contact with skin or ey es, rinse thoroughly with water. 

9.  No user serviceable parts inside,please refer to us for service. 

8.  All fog machines may splutter small amounts of fog occasionally during operation 

and for a minute or so after being turned off. 

1: SCREW  2:TELECONTROL  3:SWITCH  4:POWER INPUT 

Introduction 

Congratulations on the purchase of your new fog machine. We are confident you will 
enjoy many trouble free hours with this unit.  To assist with the care and use of the 
product we have prepared this short guide. 

Operation  

 This fog machine has been designed to function on a mains power supply of either 120V~60Hz or 
230V~50Hz and has been fitted with a suit able power plug for use with your local 
voltage. Check the label on the unit and the power plug for the correct voltage. 

Place the machine on a level surface and loosen the cap of the fluid tank to fill with 
quality water based fog fluid. We recommend use of pointed fog fluid as it has been 
specially formulated for use with our foggers . Plug the remote control unit into the 
socket at the rear and switch on to allow time to preheat. Once the machine has 
reached temperature is ready to operate the green light  on the remote control will 
illuminate. Push the button  on the remote control when  lit and hold for prolong 
bursts of fog. 

Always monitor fog fluid level as runnin g the machine with no fluid could cause 
permanent damage.  please do not touch or place anything in close proximity to the 
nozzle during operation or preheat as there is danger of burns. 

It is normal for your fogger to have a recy cling period after long bursts when the unit 
will shut itself  down for a short period in  order to heat up to  temperature. During 
this time no fog can be produced. The gr een light on the remote will illuminate when 
the unit is ready for action again. 

Due to the high operating temperature of fog machines it is advised that the effect 
be used in well ventilated areas taking care not to obstruct the air vents. After 
use,allow time to cool for safety before moving touching. 

Installation /Mounting 

The fogger must used in horizontal position sitting  level surface or it may be 
mounted using the bracket provided. Ensuring that the fog is not shooting directly at 
anyone face . 
Whatever method of installation you choose ,the fogger must not have more than a 
15 degree angle of inclination. We always suggest that safety purpose use of a 
suitable hanging clamp and safety cable is essential. We offer a range of items, 
which are ideal for safe mounting. 

 

Cleaning  

Cleaning your fog machine regularly will help reduce costly parts replacement and 
repair charges. 
After every 40 hours of continuous  operat ion or when the mach ine will be idle for a 
long time it is recommend  to run a cl eaning solution composed of 80%distilled 
water and 20% white vinegar through the  system to prevent the accumulation of 
particles in the heating  element. 

Before connecting this unit to the mains power supply for the first time you must first
fill the fluid tank with fog fluid and check that the nozzle is clean and unobstructed.