background image

WARNING: IMPORTANT SAFETY PRECAUTIONS! PLEASE READ COMPLETELY BEFORE 

                   USING PRODUCT!

When using electrical appliances, basic safety precautions should always be followed to reduce 

the risk of fire, electric shock, and personal injury, including but not limited to the following:

1. To prevent electric shock, do not operate the unit in standing water. Never plug in or unplug the unit 

    with wet hands or while standing in water.

2. To avoid risk of injury, do not direct air flow at face or body.

3. Use only with GFCI protected receptacles. Please contact a qualified electrician for verificaton and / 

    or installaton of a GFCI receptacle if necessary.

4. Do not operate any unit with a damaged cord or plug. Discard Air Scrubbers or return to an authorized 

    service facility for examination and/or repair. 

5. Air Scrubber is an automatically operated device. To reduce the risk of injury, disconnect from power 

    supply before servicing.

6. Do not run cord under carpet. Do not cover cord with throw rugs, runners, or similar coverings. Do not 

    route cord under furniture or appliances. Arrange cord away from tra

ffi

c area and where it will not be 

    tripped over.

7. Do not allow children to play with or around the Air Scrubbers at any time.

8. Do not move or carry the Air Scrubber while unit is operating.

9. Keep air intakes and exhausts clean at all times. Avoid clogging or blocking to prevent the machine 

    from overheating. Blocking the air intake could result in a fire or electrical hazards.

10. Always place the Air Scrubber on a smooth and level surface for safe operaton.

11. Unplug the unit before performing any maintenance, cleaning, or servicing. 

12. Any misuse or abuse of this product will void the warranty.

Safety Instruc�ons

Summary of Contents for X-2380

Page 1: ...X 2380 X 2480A X 2580 AIR SCRUBBER OWNER S MANUAL XPOWER MANUFACTURE INC 240 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301 Fax 626 285 3302 www xpower com...

Page 2: ...ons 7 Filtration Systems 8 9 Maintenance 9 15 Washable Nylon Pre Filters 10 Pleated Media Pre Ftlter 11 Washable Purifying Filter Care 12 Activated Carbon Filter Care 13 HEPA Filter Care 14 Filter Rep...

Page 3: ...breathing healthier with your XPOWER Professional Air Purification Equipment Features 3 4 stage air filtration system Only 2 8 amp usage with high airflow capacity from 550 CFM 5 Speed Control Easy co...

Page 4: ...ility for examination and or repair 5 Air Scrubber is an automatically operated device To reduce the risk of injury disconnect from power supply before servicing 6 Do not run cord under carpet Do not...

Page 5: ...he Air Scrubber upright on a stable flat dry surface 3 Plug the electrical cord into the power outlet 4 The unit can be used in 2 different angle positions vertical and horizontal 5 Turn the control k...

Page 6: ...r 12A the Circuit Breaker will trip If the Breaker does trip unplug the units and press the Reset button Then Plug the units back into the power souce and turn on the switch Item No Parts Name Item No...

Page 7: ...6 9 1 2 3 4 8 1819 20 21 5 7 10 11 12 13 14 15 17 16...

Page 8: ...HEPA35 33 13 x 13 x 1 4 Washable Purifying Filter Activated Carbon Filter HEPA Filter HEPA35 33 13 x 13 x 1 4 HEPA Filter DAISY CHAIN Yes FILTER CLEAN CHANGE LIGHT STACKABLE SAFETY CERTIFICATIONS ETL...

Page 9: ...13 Washable Inner Nylon Mesh Filter CF15 13 x 13 x 0 6 Activated Carbon Filter HEPA35 33 13 x 13 x 1 4 HEPA Filter Filtra on Systems X 2380 and X 2580 1st Stage 2nd Stage 4th Stage 3rd Stage X 2380 X...

Page 10: ...each of children 4 Always disconnect the Air Scrubber from its power source before performing any maintenance or cleaning Maintenance Basic routine maintenance of filters is required to optimize perfo...

Page 11: ...therefore extend the life and usage of the primary 3rd 4th Stage filters Always make sure the Air Scrubber is turned off before removing filters Before cleaning remove all debris from both the inner a...

Page 12: ...Scubber PF13 is the second stage Pre Filter to extend the life of expensive HEPA filter Pleated Air Filter gives greater particulate capture fewer IAQ complaints and do not promote bacterial growth wh...

Page 13: ...s turned off before removing filters Use vacuum or clean cloth and lay it flat on a clean surface WF50 is a washable filter Cleaning Purifying Filter WF50 1 Remove filter s and lay them on a flat clea...

Page 14: ...dequate length of time can regenerate activated carbon to the point where it can be reused The CF15 fits the X 2580 model it is placed inside the housing in front of the HEPA filter Always make sure t...

Page 15: ...respiratory problems The HEPA filter requires a simple maintenance routine which can be performed in a timely and cost effective manner To maximize HEPA filter life be sure to clean change the pre fi...

Page 16: ...ways essential for these tasks If you ve used the air scrubber for mold remediation or in another environment with known contaminants you should also consider wearing gloves eye protection and coveral...

Page 17: ...et Wiring failure Contact XPOWER for service repair Scraping noise from fan Obstruction at the intake or exhaust of fan Remove obstruction Fan broken Contact XPOWER for service repair Weak air flow Ob...

Page 18: ...ance or repair or failure to perform necessary maintenance or repair or if the use of this product is not in compliance with the instruc ons and speci ca ons for its use For Warranty service and parts...

Page 19: ...XPOWER MANUFACTURE INC Address 240 Clary Ave San Gabriel CA 91776 Tel 626 285 3301 Fax 626 285 3302 Warranty Registration Company Name Contact Person Title State Province Zip Country for US customer o...

Page 20: ...To XPOWER MANUFACTURE INC 240 Clary Avenue San Gabriel CA 91776 USA Tel 626 285 3301...

Page 21: ...0 X 2480A X 2580 Features 3 4 stage air filtration system Only 2 8 amp usage with high airflow capacity from 550 CFM 5 Speed Control Easy cord wrap design Convenient filter change clean light Stackabl...

Page 22: ...rd under carpet Do not cover cord with throw rugs runners or similar coverings Do not route cord under furniture or appliances Arrange cord away from traffic area and where it will not be tripped over...

Page 23: ...a stable flat dry surface 3 Plug the electrical cord into the power outlet 4 The unit can be used in 2 different angle positions vertical and horizontal 5 Turn the control knob to desired speed and m...

Page 24: ...r PF13 13 x 13 Pleated Media Filter WF50 13 x 13 x 2 CF15 13 x 13 x 0 6 HEPA35 33 13 x 13 x 1 4 Washable Purifying Filter Activated Carbon Filter HEPA Filter HEPA35 33 13 x 13 x 1 4 HEPA Filter DAISY...

Page 25: ...protect the inner filters from larger particles and therefore extend the life and usage of the primary 3rd 4th Stage filters Always make sure the Air Scrubber is turned off before removing filters Bef...

Page 26: ...ntenance and Replacement Fig 1 Fig 3 Fig 4 Fig 2 Filtra on System X 2480A NFS13 13 x 13 Washable Inner Nylon Mesh Filter 1st Stage HEPA35 33 13 x 13 x 1 4 HEPA Filter 3rd Stage 2nd Stage PF13 13 x 13...

Page 27: ...g the HEPA filter back into the machine make sure the side with the gasket is facing the motor housing to prevent air leakage WF50 Washable Purifying Filter as primary filter featured with the X 2380...

Page 28: ...fectiveness is noted Precautionary Measure When Cleaning and Changing Filters An air scrubber captures particles that can be hazardous to human health During the process of changing filters decontamin...

Page 29: ...PTOM POSSIBLE CAUSE ACTION Motor not running Switched off Make sure unit is plugged in and switch is turned to ON mode Power failure Check outlet change to another outlet Wiring failure Contact XPOWER...

Page 30: ...ary maintenance or repair or if the use of this product is not in compliance with the instruc ons and speci ca ons for its use For Warranty service and parts replacement US customer only you must A Ca...

Reviews: