08
09
Alarm Test
The alarm must be properly attached to the mounting bracket before it can be
tested.
1. Press the test button.
2. The unit beeps 3 times.
3. The red LED will fl ash once every second during the audible signal.
4. After testing, the alarm will automatically enter standby mode.
NOTE:
The test function accurately tests the alarm’s smoke sensing circuit without the
need to test with smoke. If your smoke alarm fails to emit an audible test signal, refer to the
troubleshooting guide at the end of this manual immediately. Never use an open fl ame to
test this device.
LED Indicator and Audible Alarm
Status
LED indicator Audible alarm
Standby Mode
Red LED flashes
once every 60 seconds.
None
Test Mode
Red LED flashes
once every second.
3 short quick beeps
Alarm Mode
Red LED flashes
once every second.
Short quick beeps
Silence Mode
Red LED flashes
once every 5 seconds.
None
Low Battery
Red LED flashes once
every 60 seconds.
1 beep every 60 seconds
01
02
03
04