background image

10

11

Malfunction   

Red LED flashes twice 
every 40 seconds. 

2 beeps every 40 seconds

Technical Specifi cations

Power Supply    

10-year sealed lithium battery (non-replaceable)

 Sensor Type    

Photoelectric

 Safety Standard     

UL 217

 C overage Area     

215–430 sq. ft (20–40 m²)

 Operating  Temperature          

40–100°F (4.4–37.8°C)

 Operating Relative Humidity 

≤ 85% (non-condensing)

 Alarm Loudness            

≥ 85 dB at 10 ft (3 m) @ 3.2 ± 0.3 kHz pulsing 
alarm

 Silence 

Duration      

About 9 minutes

NOTES 

1.  Battery life is calculated on the current ratings in the standby mode with weekly 

testings. If its operation mode changes to an alarming condition, the battery life will be 
decreased accordingly.

2. The smoke alarm functions between 40 and 100°F (4.4 and 37.8°C). Prolonged exposure 

to temperatures outside of this range can reduce battery life and aff ect accuracy. We do 

not recommend operating the device outside of this range. 

Maintenance

To keep your smoke alarm in good working order, follow these simple steps:

1. Verify the unit’s alarm sound and indicator are working properly by testing the   
    unit once a week.
2. As a minimum your smoke alarm should be cleaned once every 3 months: 
    Remove the unit from the ceiling and clean the alarm cover and vents with your     
    vacuum cleaner fi tted with the soft brush attachment to remove dust and dirt.
3. Never use detergents or other solvents to clean the unit.
4. Avoid spraying air fresheners, hair spray or other aerosols near the alarm.
5. Do not paint the unit. Paint will seal the vents and interfere with the sensor’s   
    ability to detect fi re. 
6. Never attempt to disassemble the unit or clean inside. Doing so will void your   
    warranty.
7. When removed, place the smoke alarm back in its proper location as soon as   
    possible, to assure continuous protection from fi re.
8. When household cleaning supplies or similar contaminants are used, the area  
    should be ventilated.

Troubleshooting

PROBLEM 

SOLUTION

Your smoke alarm does not sound 
during testing.

• Please check whether the alarm is properly 

attached to the mounting bracket.

• Make sure you push the test button fi rmly.

Summary of Contents for XS03

Page 1: ...F 1 05 XS0305 Photoelectric Somke Alarm User Manual Model XS03 X Sense Innovations Co Ltd Email support x sense com ...

Page 2: ...ng improved and expanded Visual and Audible Alerts During an emergency the unit will alarm at 85 dB within a distance of 3 meters and a red LED indicator will flash in sync with the alarm tone Battery Operated A long life lithium battery sealed inside the alarm ensures a 10 year lifetime in standby condition Silence Mode Silence your smoke alarm by momentarily pressing the test silence button when ...

Page 3: ... 1 NEVER IGNORE ANY ALARM FAILURE TO RESPOND CAN RESULT IN SERIOUS INJURY OR DEATH 2 THE SILENCE FEATURE IS ONLY FOR YOUR CONVENIENCE AND WILL NOT CORRECT A PROBLEM ALWAYS CHECK YOUR HOME FOR A POTENTIAL PROBLEM AFTER ANY ALARM FAILURE TO DO SO CAN RESULT IN INJURY OR DEATH 3 TEST THIS SMOKE ALARM ONCE A WEEK IF THE ALARM EVER FAILS TO TEST CORRECTLY REPLACE IT IMMEDIATELY IF THE ALARM CANNOT WORK...

Page 4: ...oke heat and anything burning will spread horizontally after rising to the ceiling so install the alarm in the middle of the ceiling where possible Ensure that the alarm is installed at the minimum distance away from corner 4 If an alarm cannot be installed in the middle of a ceiling install it at a distance of 20 inches 50 cm away from the corners of the room 5 If an alarm is installed onto a wal...

Page 5: ... ACCORDANCE WITH THE INSTALLATION INSTRUCTIONS 4 BATTERIES SHOULD NOT BE EXPOSED TO EXCESSIVE HEAT SUCH AS DIRECT SUNLIGHT FIRE ETC Installation Method 1 Use the mounting bracket to mark the screw holes on the ceiling or the wall 2 Drill holes at the 2 marks using an appropriately sized drill bit Insert the anchor plugs and screw the mounting bracket using the screws provided 3 Attach the alarm to...

Page 6: ...est with smoke If your smoke alarm fails to emit an audible test signal refer to the troubleshooting guide at the end of this manual immediately Never use an open flame to test this device LED Indicator and Audible Alarm Status LED indicator Audible alarm Standby Mode Red LED flashes once every 60 seconds None Test Mode Red LED flashes once every second 3 short quick beeps Alarm Mode Red LED flash...

Page 7: ...working order follow these simple steps 1 Verify the unit s alarm sound and indicator are working properly by testing the unit once a week 2 As a minimum your smoke alarm should be cleaned once every 3 months Remove the unit from the ceiling and clean the alarm cover and vents with your vacuum cleaner fitted with the soft brush attachment to remove dust and dirt 3 Never use detergents or other solv...

Page 8: ...e replaced Red LED flashes and the alarm sounds 2 beeps every 40 seconds The alarm is malfunctioning Please clean your smoke alarm and see if it is working normally If not replace the device immediately Environmental Protection Waste electrical products should not be disposed of with household waste Please recycle where facilities exist Check with Local Authority or retailer for recycling advice M...

Reviews: