background image

20

j. Device Power-up Count

-

Number of “Fire” button press counts for device power up.

-

Default is 3 times.

Summary of Contents for ARES

Page 1: ...1 ARES User Manual V1 10 ...

Page 2: ...ohibited to open body of the device otherwise warranty will be void Do not expose device to heat source for long period It might damage the battery Warning Abnormal operation may damage the device This product is strictly for above 18 years only Open Box Basic configuration 1 1x ARES device 2 1 x USB cable support up to 2A 3 1 x user manual ...

Page 3: ... for fully charge battery Coil resistance o Measurement range 0 04Ohm 10Ohm o Resolution 1m Ohm based on 0 1ohm measurement Power control mode o Recommended resistance range 0 08Ohm 3Ohm o Coil over heat protection Refer to coil material table for detail Temperature control mode o Recommended resistance range 0 08Ohm 2Ohm o Repeatability 1 degree Celsius 1 8 Fahrenheit o Support Ni 200 Ti 01 02 SS...

Page 4: ...ircuit protection o Weak battery protection o Battery over charge protection o Battery over load protection o 10 seconds maximum fire duration protection Support firmware upgrading through USB port Screen lock features Coil resistance measurement features Real time display data during fire on o Battery voltage capacity o Coil resistance power mode o Sensing coil temperature temperature mode o Coil...

Page 5: ... 100 316 Degree C 212 600 Fahrenheit 1 Degree C 1 Fahrenheit NiFe30 Stealth Vape 331 Degree C 628 Fahrenheit 100 316 Degree C 212 600 Fahrenheit 1 Degree C 1 Fahrenheit NiFe70 331 Degree C 628 Fahrenheit 100 316 Degree C 212 600 Fahrenheit 1 Degree C 1 Fahrenheit SSL316L 331 Degree C 628 Fahrenheit 100 316 Degree C 212 600 Fahrenheit 1 Degree C 1 Fahrenheit Nichrome N60 331 Degree C 628 Fahrenheit...

Page 6: ...6 Structure Diagram Fire Button Left Button Right Button ...

Page 7: ...tton 3 times to power up devices This design is to avoid fire being trigger accidently Device auto enter power off mode after 6 minutes of idling 3 Operation Coil Resistance measurement Press Left Right for coil resistance measurement Firmware version ...

Page 8: ... Left to switch different preset memory setting Press Left Right for coil resistance measurement Press fire button to start fire Under MENU Control select Wattage to enter power mode Fire mode Powerful giving 10 more power than Standard mode configuration Fire mode Soft giving 10 less power than Standard mode configuration Target power Preset memory Coil material Fire mode Soft Standard Powerful E...

Page 9: ...e temperature setting Long press Right to enter main menu Short press Left to switch different preset memory setting Press Left Right for coil resistance measurement Press fire button to start fire Under MENU Control select Temp to enter temperature mode Example of Ni 200 Target temperature 275 degree C Starting power 220W Starting power Preset memory Coil material Temperature control mode indicat...

Page 10: ... sub menu 7 Operation Main Menu Control Press Right Left to switch menu setting Press fire button to confirm control mode setting Coil type selection Control mode Battery health checking Puff counter info Power off device Exit main menu Power mode Preset memory Temperature mode Device setting ...

Page 11: ...chrome N60 Kanthal A1 NiFe30 NiFe70 SS316L Please refer to coil material table for detail 9 Operation Main Menu Coil TCR Customize TCR setting for unknown coil material or non single wrapping coil Select Coil TCR Short press or long press Right Left to adjust coil TCR value TCR Range 0 00040 0 01000 Press fire button to confirm the TCR value Preset memory ...

Page 12: ...nfigure date before start using puff info counter a Example Day Puff Info Puff counter info based on day Puff counter info based on week Puff counter info based on month Read Configure system date Clear Puff info data Counter Total time s seconds m minutes ...

Page 13: ...ery health Atomizer with coil must be connected during health measurement Otherwise will indicate Check Error Recommended coil resistance range 0 1 1 ohm for battery health check User should consider replace battery if health condition was bad Good Degraded Bad Battery temperature Battery Capacity in ...

Page 14: ...14 12 Device Setting Screen Brightness Screen turn ON duration Stealth mode Language Device info Reverse button Left and Right polarity Wake up method Temperature unit Device power up count ...

Page 15: ...djustment of the OLED screen Four brightness stages selection Default is Bright b Screen Turn ON duration OLED screen turn ON time duration Default is 15 seconds Choosing short turn ON duration will able increase a bit battery life time ...

Page 16: ...ff OLED main screen during Fire On if stealth mode Enable Default is Disable d Wake up method Device only occupies 44 5uA during standby sleep mode Wake up mode was the way of device wake up from standby sleep mode Default is Smart ...

Page 17: ...s allows device to avoid fire being trigger accidently If device power off manually menu power off both smart and normal mode still required short press Fire button 3 times to power up devices e Language Support 10 multi languages English Simplify Chinese Italian Russian Spanish German French Portuguese Dutch and Malay Default is English ...

Page 18: ...erial number of the device the serial number should match with the barcode label at the battery slot of the device g Reverse button Right and Left polarity Normal Right Up Increase Left Down Decrease Reverse Left Up Increase Right Down Decrease ...

Page 19: ...Right Left to switch temperature unit setting Press fire button to confirm temperature unit setting i Reverse button Right and Left polarity Normal Left Up Increase Right Down Decrease Reverse Right Up Increase Left Down Decrease ...

Page 20: ...20 j Device Power up Count Number of Fire button press counts for device power up Default is 3 times ...

Page 21: ...21 13 Battery charging Real time monitoring battery temperature during charging Charing percentage Charging indicator Battery cell balancing Battery temperature Charging elapsed time ...

Page 22: ...then fire button from power off mode Upgrading firmware through USB port Device X Taste Comm Port will be found after installation of the driver Download latest firmware from official X Taste web site and follow instruction to upgrade firmware ...

Page 23: ...oftware X Taste Advance software allow user to modify setting and operation of the device For the advance user who need to customize the setting of the device 16 Lock Unlock The lock feature prevents accidently firing Short press Fire button 3 times to lock unlock devices Lock screen while charging battery ...

Page 24: ...ncrease maximum coil temperature to ignore this warning Coil Current Too High Maximum allow continuous coil current was 40A Try reducing the power Coil Not Support Kanthal A1 and Nichrome not support temperature control mode Abnormal coil Coil behaves abnormal Please check the atomizer and the coil type setting If not sure coil material type for none temperature control atomizer please set coil ma...

Page 25: ...upply sufficient current Check battery capacity else please check battery health Bad battery contact Bad battery contact Please reinstall battery using proper method Board Too Hot Device PCB temperature too high Driver Faulty 1 Driver error warning Try to increase power if setting power too low Fire time out 10 sec Maximum fire allow duration was 10 seconds ADC Check coil ADC error Please retry fi...

Page 26: ...y X Taste Official Website www x taste com Email support x taste com sales x taste com Address No 2 Yihe Road Shilong Community Shiyan Street Baoan District b ShenZhen City China Designed in Singapore Assembled in China ...