DiagCCP > Advanced:
1 Add basic structure of the function
3 Execute function
2 Input data
This category displays an overview of the configured event channels and
allows the definition of a seed and key function for the encrypted
communication with the ECU.
Create and test the seed and key function:
Click
Add basic structure of the function
(1)
.
Insert the algorithm that corresponds with the ECU.
Define the
Input data
(2)
to test the function.
Click
Execute function
(3)
.
The X
ORAYA
Suite calculates the output data (key) from the input data
(seed) and compares it with the key calculated by the ECU.