U
SER
M
ANUAL
X
ORAYA
Z7
|
X
ORAYA
ML-Z7
X
ORAYA
S
UITE
126
5.7.2
HDD mode
In this mode, the datalogger saves to one of the following media:
▪
Internal storage medium (default)
▪
USB flash drive if
Record on USB stick
in the
Hard Disk
category is
checked and the conditions described there are met (
➔
▪
Additional device X
ORAYA
ESU (automatically if detected by the
datalogger)
Start data recording:
Connect the datalogger to the measurement environment.
(
➔
Connecting the datalogger to the measuring environment)
Optionally:
Connect a USB flash drive to the USB host port
(C)
.
(
➔
Optionally:
Connect a X
ORAYA
ESU to the corresponding port
(F)
.
Turn on the datalogger.
Start the HDD recording by pressing the trigger button
(J)
on the
datalogger.
Data received via the interfaces are recorded.
Stop data recording:
Press the trigger button
(J)
for at least 3 seconds.
Configuration of trigger button
The behavior of the trigger button can be configured via
the button interface. (
➔
HDD mode in the X
ORAYA
Suite
You can also start and stop the HDD mode from the
Configuration
,
Online-Logging
,
Hdd-Download
and
Firmware-Update
tools.
Data recorded on the storage medium is stored as sessions. Sessions always
contain complete messages and are limited to a maximum size which
defaults to 1000 MB.