background image

5

Connect 

Solution Hose  

Here

REAR VIEW

FRONT VIEW

Latches

Power 

Cord 

Pigtails

Loading

Wheels

Switches 

& Green 

Light

{

Wand

Holder

Recovery 

Tank Access

Recovery 

Tank Drain 

Hose

Solution 

Hose 

connects 

here

Recovery 

Hose 

connects 

here

Solution

Tank 

Fill Hole

Swivel 

Castor

VIEWS OF THE MACHINE:

Pump 

Switch

Vacuum 

Switch

Heat 

Switch

Select II 

for high 

heat or 

for low 

heat. 

Center 

position is 

off

Green 

Light 

informs the 

operator when 

the power cords 

are plugged into 

separate circuits

Summary of Contents for Xtract 200

Page 1: ...1 78 00018 Rev B 032912 XAACT Xtract 200 READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE OPERATING THE MACHINE INFORMATION OPERATING INSTRUCTIONS ...

Page 2: ...Float Dimensions 36 3 4 H 23 1 2 W 32 L Weight 98 lbs Warranty 2 year limited lifetime on body heater Care Maintenance 4 Views of Machine 5 Set up Operating Instructions 6 Part List 7 Exploded View 8 Warranty 9 Troubleshooting 10 CONTENTS RECORD AND RETAIN THIS IMPORTANT INFORMATION And don t forget to register your purchase to activate your warranty Model Xaact Xtract 200 Serial Number Purchase D...

Page 3: ...mes in temperature Store in a heated location Use the machine indoors Do not use outdoors Do not use this machine to dry vacuum before wet cleaning Do not use with damaged cord or plug If the machine is not working as it should has been dropped damaged left outdoors or flooded with water return it to a service center Do not leave the machine unattended when it is plugged in Unplug the unit from th...

Page 4: ...machine always use a cleaner with a pH as close to neutral as possible to avoid premature wear of the pump seals and or other components Damage caused by the use of strong chemicals is not covered by the warranty The use of powder chemicals is discouraged unless they are mixed very thoroughly and rinsed out completely at the end of the job powdered cleaners could cause a build up in the pump lines...

Page 5: ...k Access Recovery Tank Drain Hose Solution Hose connects here Recovery Hose connects here Solution Tank Fill Hole Swivel Castor VIEWS OF THE MACHINE Pump Switch Vacuum Switch Heat Switch Select II for high heat or I for low heat Center position is off Green Light informs the operator when the power cords are plugged into separate circuits ...

Page 6: ... wait two minutes for the heater to reach operating temperature 8 Pre spray the area to be cleaned with the detergent of your choice NOTE If you choose to add a detergent to the solution tank be sure to mix well and always follow the use dilution instructions on the chemical label Use a chemical with a pH between 5 and 10 to reduce the likelihood of premature wear to the pump and other seals 9 Tur...

Page 7: ...3 stage 14A 80 00182 1 Gasket vacuum 5 OD 15 50 00042 2 Power cord 25 ft 15A 50 00043 2 Power cord pigtail 16 50 00062 1 Filter pump inlet 17 80 00212 1 Axle 17A 40 00036 2 Axle cap 18 88 00012 1 Heater complete 18A 30 00145 1 Repair kit complete for heater 19 80 00131 2 Caster 20 80 00185 1 Plate 21 80 00172 2 Wheel 12 inch 22 40 00044 8 Hose clamp 23 40 00020 2 Washer high temp 24 80 00051 1 Qui...

Page 8: ...XTRACT 200 Heated 120V 1 3 4 5 7 8 9 11 13 14 15 17 19 20 22 25 31 18 18A 10 12 22 17A 30 22 16 24 27 27 28 15A 2 12A 32 22 8A 21 23 14A 6 35 34 33 Rev 040312 8 26 ...

Page 9: ...ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED TO THE DURATION OF THIS WARRANTY Some states do not allow limitations on how long an implied warranty lasts so the above limitations may not apply to you XAACT PRODUCTS SHALL IN NO WAY BE LIABLE FOR INJURIES TO PROPERTY OR FOR INJURY OR DEATH TO PERSONS OR FOR INCIDENTAL CONTINGENT SPECIAL OR CONSEQUENTIAL DAMAGE ARI...

Page 10: ...wer to cord on off switch is bad Low suction recovery tank lid not closed damaged vacuum gasket dirty vacuum inlet screen vacuum hose loose or cracked No suction recovery tank is full vacuum not running bad switch or bad vacuum motor Low heat spraying too long No heat no power to heating element thermal fuse is blown one or both of the bimetallic switches is not closing or heat selector switch is ...