Spray system calibration (with clean water) should be conducted on a regular basis as the use of
corrosive liquid and viscous liquid during the daily operation or replacement of peristaltic pump may
lead to excessive deviation.
After the calibration is completed, Inspect and ensure the health index is normal (1.2-1.4). If the health
index remains abnormal after calibration, check and ensure the Peristaltic pump tubes and Spray
Tubes are not shrivelled, deformed or lost its elasticity. Replace tubing if any of the above symptoms
are found.
• Peristaltic Pump
01. Disassemble the Peristaltic pump and ensure the peristaltic pump tube and the roller are
sufficiently lubricated. Apply Vaseline if the lubrication is poor.
02. Check and ensure the cable connectors on the Pump Controller Board are firmly secured, and
there is no oxidation, and etc.
• Liquid Tank
01. Check and ensure the sealing ring of the liquid inlet are intact.
02. Unscrew the Cap, then check and ensure the inner tubes are in good condition.
03. Unscrew the filter and ensure the filter are kept clean, free of foreign objects and no
deformation.