41
XAG AUSTRALIA
Changing the Spiral Feeder
01. Begin by disconnecting the Spreader Motor Cable.
02. Proceed by releasing the hasp on the Quick Assembly unit. Once it has been released, carefully
remove the Quick Assembly Unit from its position.
03. Identify the three screws that secure the Spiral Feeder in place. With a suitable tool, unscrew
these, then carefully remove the Spiral Feeder from its compartment.
04. Install the new Spiral Feeder into the designated spot. Confirm that it fits accurately before
securing it firmly in place with the three screws.
05. Return the Quick Assembly Unit to its original position, ensuring it aligns correctly with the
associated fittings.
06. Once aligned, tighten the hasp to fix the Quick Assembly Unit in place. Following its successful
fixation, reconnect the Spreader Motor Cable, ensuring the cable is firmly connected to prevent
any loose connections.
07. Finally, conduct a thorough calibration to confirm the RevoCast System is functioning as
intended. Please refer to the 'Calibration - RevoCast' section of this manual for a detailed guide
on this procedure.