820-0332
3-1
Installation
X7110 and X 7120 MICRO-Z Inker Installation
The X7120 Motorized and X7110 Manual Micro-Z pneumatic inkers are for use with
wafer probing and wafer inspection equipment from multiple OEMs. Both Manual and
Motorized models are installed using two 4-40 x 1.25" Shoulder Head Cap Screws
(SHCS)
1.
If you are currently using another inker, remove it from the prober/ equipment.
Move the chuck/wafer from underneath the inker when
installing
inker to prevent damage
.
2.
Install the inker base onto the prober using the two (2) supplied 4-40 x 1.25"
SHCS. Torque to 8.0 inch-pounds (in-lbs).
X7110 Manual Micro-Z Inker Assembly
X7110 MANUAL
INKER BASE
ASSEMBLY
PNEUMATIC
SHUTTLE
ASSEMBLY
CONTROLLER-TO-
SHUTTLE AIR HOSE:
CONNECT TO LARGE
“SHUTTLE” PORT
CARTRIDGE FITTING
(RED HOSE)
MICRO-Z
ADJUSTMENT
DIAL
2X 4-40 x 1.25"
INSTALLATION
SCREWS
Summary of Contents for 340-7110
Page 10: ...1 2 820 0332 This page is intentionally left blank...
Page 18: ...Controller Installation Installation 3 6 820 0332 This page is intentionally left blank...
Page 34: ...Cartridge Priming Tips System Operation 820 0332 4 16 This page is intentionally left blank...
Page 40: ...Ink Removal Information Ink 820 0332 5 6 This page is intentionally left blank...