Controller Preventive Maintenance
Maintenance &
Troubleshooting
820-0332
6-6
Problem
Solution
“STATUS” & “INK ON” LED's
Flashing
1.
Verify that there is air input to the
controller.
2.
Unacceptable mode switch
combination. Review
“Controller
Operation” in Section 4.
Dot size does not change with
adjustment of Dot Size Thumbwheels
1.
Verify that the air hoses from the
controller to the inker are connected
properly:
♦
RED AIR HOSE connects to the ink
cartridge.
♦
BLUE AIR HOSE connects to the
shuttle connection on the shuttle
mechanism.
2.
Replace ink cartridge.
Controller Preventive Maintenance
Pneumatic Controller Preventive Maintenance Schedule and Kits
The preventive maintenance kit for the 350-0027 Micro-Z Pneumatic Controller is Part
Number 370-0108. See the included instruction for maintenance procedure and schedule.