background image

 

Defender XD103- User Manual

 

 

WARNING: HAZARDOUS VAPORS. 

Spray materials, solvents, and other materials can be harmful

 

if inhaled or come in contact with the body. Vapors can cause severe nausea, fainting, or poisoning.

 

To avoid these risks, take the following preventions:

 

• Keep spray area well ventilated.

 

• Use a respirator or mask as vapors can be inhaled. Read all instructions supplied with the mask to ensure proper use.

 

• Wear protective eyewear.

 

• Wear protective clothing as required by disinfectant manufacturer.

 

 

WARNING: ELECTRIC SHOCK HAZARD

. May cause severe injury.

 

To avoid these risks, take the following preventions

 

• Keep electrical cord plug and atomizer trigger free from spray material and other liquids. Never hold cord at plug

 

connections to support cord or product. Failure to observe may result in an electrical shock and death.

 

• Never immerse electrical parts in water or any other liquid. Wipe the exterior of the atomizer with a damp cloth to wipe 

away unwanted materials. Always make sure the atomizer is unplugged before taking it apart for cleaning.

 

• Do not expose unit to rain or wet conditions.

 

• Do not abuse the cord. Never use the cord to carry the unit or pull the plug from an outlet. Keep cord away from heat,

 

oil, sharp edges or moving parts. Replace damaged cords immediately.

 

• Do not store atomizer with liquid in the canister.

 

• Do not operate nor store atomizer on its side or inverted when liquid is in the canister.

 

• The suction tube in the canister should always be submerged in the liquid in the canister when in use. Do not operate the 

atomizer in a manner/attitude that allows the suction tube to become unsubmerged. Examples of improper use include (but 

are not limited to) use while inverted or use while being held sideways. Bubbling of the liquid in the canister indicates 

improper use.

 

 

WARNING: SKIN INJECTION HAZARD

. May cause severe injury.

 

To avoid these risks, take the following preventions

 

• NEVER aim the atomizer at any part of the body.

 

• Do not aim the atomizer at or spray any person or animal.

 

• NEVER allow any part of the body to come in contact with the fluid stream.

 

• NEVER put your hand in front of the atomizer. 

 

- ALWAYS wear gloves while operating the unit; however, gloves will not provide protection against an injection injury.

 

• Keep hands and other body parts away from the discharge. For example, do not try to stop leaks with any part of the    body.

 

• Always unplug the atomizer before servicing, cleaning tip guard, changing tips, or leaving unattended.

 

• Always use the nozzle tip guard. Do not spray without nozzle tip guard in place.

 

• Only use a nozzle tip specified by the manufacturer.

 

• Use caution when cleaning and changing nozzle tips. In the case where the nozzle tip clogs while spraying, follow the 

manufacturer’s instructions.

 

• High-pressure spray is able to inject toxins into the body and cause serious bodily injury. In the event that injection

 

occurs, seek medical attention immediately.

 

• Verify that all connections are secure before operating the unit.

 

GENERAL SAFETY WARNINGS

 

Summary of Contents for XD103

Page 1: ...Electric Atomizer for Disinfecting INSTRUCTIONS FOR HVLP ELECTRIC ATOMIZER XD103 Before using the atomizer read this manual thoroughly Any improper use can cause damage or serious injury including death ...

Page 2: ...Defender XD103 User Manual Disinfecting Log Sheet Area Disinfected Chemical Used Date Time ...

Page 3: ... property damage can occur Only clean up with water or soap water To avoid these risks take the following preventions Exhaust and fresh air introduction must be provided to keep the air within the spray area free from accumulation of flammable vapors Keep spray area well ventilated Avoid all ignition sources such as static electricity sparks open flames pilot lights hot objects lit tobacco product...

Page 4: ... liquid is in the canister The suction tube in the canister should always be submerged in the liquid in the canister when in use Do not operate the atomizer in a manner attitude that allows the suction tube to become unsubmerged Examples of improper use include but are not limited to use while inverted or use while being held sideways Bubbling of the liquid in the canister indicates improper use W...

Page 5: ...ate or spray near children Keep children away from equipment at all times Keep atomizer out of the reach of children Do not overreach or stand on an unstable support Keep effective footing and balance at all times Stay alert and watch what you are doing Do not operate the unit when fatigued or under the influence of drugs or alcohol Read all instructions and safety precautions for equipment and sp...

Page 6: ...Defender XD103 User Manual ...

Page 7: ...e cover 28 Cannister 45 Motor cover 12 Big nut 29 Φ3 flat gasket 46 Motor 13 Air cap 30 Foot pad 47 Damping ring 14 Atomizer nozzle 31 Short pin 15 Barge board 32 Adjusting knob 16 Nozzle seal 33 Trigger 17 Needle 34 Atomizer knob II Technical parameters Model XD103 Rated power 550W Atomized particle size nominal 60 80 microns when used with water thin disinfectant Rated voltage 120V Spray distanc...

Page 8: ...uction tube should be pointing toward the front of the atomizer c Do not operate nor store atomizer on its side or inverted when liquid is in the canister d The suction tube in the canister should always be submerged in the liquid in the canister when in use Do not operate the atomizer in a manner attitude that allows the suction tube to become unsubmerged Examples of improper use include but are ...

Page 9: ... it counterclockwise 90 degrees c Pull out to remove the motor blower from the atomizer 6 Screw filled disinfectant container onto the atomizer 7 Connect atomizer body with motor blower a Hold atomizer body in your left hand and align the slot on the atomizer with the slot on the motor blower and insert as shown in the figure b Rotate the motor blower 90 degrees clockwise c When the atomizer and m...

Page 10: ...r desired level of disinfectant coverage a Adjust the screw to the left to decrease coverage b Adjust the screw to the right to increase coverage 9 Spray pattern adjustment Turn the knob to adjust from round pattern to fan pattern Adjusting Screw Spray Pattern Adjustment Knob ...

Page 11: ...er s recommendations for dwell time for the specific disinfectant being applied a If surfaces remain wet longer than 5 10 minutes increase movement speed of the atomizer to produce a lighter coating b If surfaces are not fully wetted slow down movement speed of the atomizer V Maintenance 1 Cleaning a Unplug unit from outlet b Separate atomizer from motor blower assembly c Remove disinfectant conta...

Page 12: ...ogged 3 too little pressure build up in container 1 turn to the right 2 clean 3 tighten container D spray jet pulsates 1 material in container is depleted 1 refill E pattern runs sags or remains wet 1 applying too much material 1 adjust material flow or increase movement of atomizer F too much over spray 1 atomizer too far from target area 2 too much material applied 1 reduce distance 2 turn mater...